On 4/11/22 17:15, Peter Maydell wrote:
The semantic difference between the deprecated device_legacy_reset()
function and the newer device_cold_reset() function is that the new
function resets both the device itself and any qbuses it owns,
whereas the legacy function resets just the device itself and nothing
else.
In s390-pci-inst.c we use device_legacy_reset() to reset an
S390PCIBusDevice. This device doesn't have any child qbuses, so the
functions do the same thing and we can stop using the deprecated one.
Reviewed-by: Matthew Rosato <mjros...@linux.ibm.com>
Signed-off-by: Peter Maydell <peter.mayd...@linaro.org>
---
hw/s390x/s390-pci-inst.c | 2 +-
1 file changed, 1 insertion(+), 1 deletion(-)
Reviewed-by: Philippe Mathieu-Daudé <phi...@linaro.org>