On 7/2/21 12:40 PM, Peter Maydell wrote:
> The PL061 comes out of reset with all its lines configured as input,
> which means they might need to be pulled to 0 or 1 depending on the
> 'pullups' and 'pulldowns' properties.  Currently we do not assert
> these lines on reset; they will only be set whenever the guest first
> touches a register that triggers a call to pl061_update().
> 
> Convert the device to three-phase reset so we have a place where we
> can safely call qemu_set_irq() to set the floating lines to their
> correct values.
> 
> Signed-off-by: Peter Maydell <peter.mayd...@linaro.org>
> ---
>  hw/gpio/pl061.c      | 29 +++++++++++++++++++++++++----
>  hw/gpio/trace-events |  1 +
>  2 files changed, 26 insertions(+), 4 deletions(-)

Nice.

Reviewed-by: Philippe Mathieu-Daudé <f4...@amsat.org>