On 18.02.19 13:27, David Hildenbrand wrote: > We already forward the 3 bits correctly in the translation functions. We > also have to handle them properly and check for specification > exceptions. > > Setting an invalid rounding mode (BFP only, all DFP rounding modes) > results in a specification exception. Setting unassigned bits in the > fpc, results in a specification exception. > > This fixes LOAD FPC (AND SIGNAL), SET FPC (AND SIGNAL). Also for, > SET BFP ROUNDING MODE, 3-bit rounding mode is now explicitly checked. > > Note: TCG_CALL_NO_WG is required for sfpc handler, as we now inject > exceptions. > > We won't be modeling abscence of the "floating-point extension facility" > for now, not necessary as most take the facility for granted without > checking. > > z14 PoP, 9-23, "LOAD FPC" > When the floating-point extension facility is > installed, bits 29-31 of the second operand must > specify a valid BFP rounding mode and bits 6-7, > 14-15, 24, and 28 must be zero; otherwise, a > specification exception is recognized. > > Signed-off-by: David Hildenbrand <da...@redhat.com>
Here as well, Reviewed-by: Richard Henderson <richard.hender...@linaro.org> -- Thanks, David / dhildenb