On 21/07/2017 15:42, Gerd Hoffmann wrote:
On Fri, 2017-07-21 at 15:15 +0300, Marcel Apfelbaum wrote:
On 21/07/2017 13:04, Gerd Hoffmann wrote:
    Hi,

What about window sizes?  IIRC there was a plan to provide
allocation
hints for them too ...

Yes, is in my TODO list, however not as part of Aleksandr's
series
which aims to provide PCIe-PCI bridge hotplug support.

I'd prefer to have a single vendor capability for all resource
allocation hints provided by qemu.


[Adding Laszlo]


Sure, the capability looking something like:

     [flags: reserve-buses|reserve-IO|reserve-MEM|...]
     [extra-buses][IO-size][MEM-size]

     if reserve-buses -> use 'extra-buses' value and so on

Do we need the flags?  We can use "value == 0 -> no hint for you".

Maybe we don't want to allocate IO at all,
So value 0 would say do not allocate.

But we can disable IO by other means.

Also what about prefetchable vs. non-prefetchable memory?  I guess we
want a size hint for both memory windows?


Good point, thanks!
Marcel


cheers,
   Gerd