On 21 March 2017 at 17:59, Jiahuan Zhang <jiahuanzhan...@gmail.com> wrote:
> > > On 21 March 2017 at 17:50, Peter Maydell <peter.mayd...@linaro.org> wrote: > >> On 21 March 2017 at 16:47, Jiahuan Zhang <jiahuanzhan...@gmail.com> >> wrote: >> > The actual situation is, pl011_can_receive is returning false, the fifo >> is >> > full, pl011_read does't start. >> > At this moment, only pl011_can_recieve is keeping returning 0. >> >> OK, so the incoming data has filled up the FIFO, and the UART >> is now sitting waiting for the guest to read the data... >> > > Yes. And I think the guest reading can start when the fifo is nonempty. > In the guest program, I first check the flag register, once the fifo is > nonempty, > then move on to read from the data register. > > This works to read small data, smaller than 16 bytes. > >> >> >> * whether pl011_can_receive is returning true even with >> >> 16 bytes in the fifo (hard to see how, given the code) >> >> * whether the fifo actually has fewer bytes in it because >> >> the guest is reading them >> > >> > >> > No, because the guest application does't get any data. >> >> ...so if the guest isn't getting any data that suggests it's >> the guest code's bug (ie it is not actually reading out of >> the FIFO). >> > > What I found is pl011 expects to read all the data into fifo, > though pl011_can_receive returns false. > Only when all the data is read, pl011_read can start. > The only thing I can consider about my guest application is the interrupt. Since in pl011_put_fifo(), *if* (s->read_count == s->read_trigger){ s->int_level |= PL011_INT_RX; pl011_update(s); } I try to enable the interrupt in the guest program, but still not work. >> thanks >> -- PMM >> > >