On Wed, Jun 16, 2010 at 12:40:28AM +0200, Jan Kiszka wrote: > From: Jan Kiszka <jan.kis...@siemens.com> > > There is no need starting with the special value for hpet_cfg.count. > Either Seabios is aware of the new firmware interface and properly > interprets the counter or it simply ignores it anyway. > I want seabios to be able to distinguish between old qemu and new one. Hence special value. I used it incorrectly in may v2 seabios patch. Will resend asap. Will teach me to not change logic at the last minute :( I removed "valid" field between v1 and v2 of the patches and introduces special value for count instead. As a result I made one bug in qemu and one is seabios. Heh.
> Signed-off-by: Jan Kiszka <jan.kis...@siemens.com> > --- > hw/hpet.c | 7 +------ > 1 files changed, 1 insertions(+), 6 deletions(-) > > diff --git a/hw/hpet.c b/hw/hpet.c > index d5c406c..ed4e995 100644 > --- a/hw/hpet.c > +++ b/hw/hpet.c > @@ -74,7 +74,7 @@ typedef struct HPETState { > uint8_t hpet_id; /* instance id */ > } HPETState; > > -struct hpet_fw_config hpet_cfg = {.count = UINT8_MAX}; > +struct hpet_fw_config hpet_cfg; > > static uint32_t hpet_in_legacy_mode(HPETState *s) > { > @@ -682,11 +682,6 @@ static int hpet_init(SysBusDevice *dev) > int i, iomemtype; > HPETTimer *timer; > > - if (hpet_cfg.count == UINT8_MAX) { > - /* first instance */ > - hpet_cfg.count = 0; > - } > - > if (hpet_cfg.count == 8) { > fprintf(stderr, "Only 8 instances of HPET is allowed\n"); > return -1; > -- > 1.6.0.2 -- Gleb.