On 27.02.15 00:19, Cyril Bur wrote:
> This patch adds basic support for the VTB.
> 
> PowerISA:
> The Virtual Time Base (VTB) is a 64-bit incrementing counter.
> Virtual Time Base increments at the same rate as the Time Base until its value
> becomes 0xFFFF_FFFF_FFFF_FFFF (2 64 - 1); at the next increment its value
> becomes 0x0000_0000_0000_0000. There is no interrupt or other indication when
> this occurs.
> 
> The operation of the Virtual Time Base has the following additional
> properties.
> 1. Loading a GPR from the Virtual Time Base has no effect on the accuracy of
> the Virtual Time Base.
> 2. Copying the contents of a GPR to the Virtual Time Base replaces the
> contents of the Virtual Time Base with the contents of the GPR.
> 
> Signed-off-by: Cyril Bur <cyril....@au1.ibm.com>

Thanks, applied to ppc-next.


Alex

Reply via email to