On Thu, Aug 14, 2014 at 12:13:51PM -0400, John Snow wrote:
> 
> 
> On 08/14/2014 12:09 PM, Stefan Hajnoczi wrote:
> >On Wed, Aug 13, 2014 at 05:56:12PM -0400, John Snow wrote:
> >>@@ -497,6 +495,8 @@ static void ahci_reset_port(AHCIState *s, int port)
> >>      pr->scr_stat = 0;
> >>      pr->scr_err = 0;
> >>      pr->scr_act = 0;
> >>+    pr->tfdata = 0x7F;
> >
> >Is it possible to avoid the magic number?
> >
> 
> I can name it as AHCI_TFD_BOOT_VALUE or AHCI_TFD_INIT_VALUE or so. Same for
> the PxSIG boot value too. I don't think I can give any greater meaning to
> the value because it's just a boot signature that means "We haven't received
> an FIS yet."

In that case, don't bother.  I thought this was error and status fields
shifted.

Stefan

Attachment: pgpBMIhp2oiIA.pgp
Description: PGP signature

Reply via email to