On 03/21/13 01:31, Laszlo Ersek wrote: > On 03/21/13 00:45, Eric Blake wrote: >> On 03/20/2013 05:23 PM, Laszlo Ersek wrote:
>>> +# >>> +# @oem_id: #optional OEM identifier (6 bytes) >> >> s/oem_id/oem-id/ >> >> In general, new QMP interfaces should use '-', not '_'. > > Indeed! I think this warrants a respin. Actually it doesn't, apologies -- I got confused for a minute. Again, since I aim to match the existing option format, I must keep the same spelling. Thanks, Laszlo