Andreas Färber <afaer...@suse.de> writes:

> Am 11.02.2013 05:59, schrieb David Gibson:
>> Currently the spapr-vlan device does not supply a cleanup call for its
>> NetClientInfo structure.  With current qemu versions, that leads to a SEGV
>> on exit, when net_cleanup() attempts to call the cleanup handlers on all
>> net clients.
>> 
>> Signed-off-by: David Gibson <da...@gibson.dropbear.id.au>
>
> Tested-by: Andreas Färber <afaer...@suse.de>
>
> On Anthony's request I posted a patch that adds back the if surrounding
> the cleanup callback, fixing also the other affected nics.
Since this cleanup hook doesn't do anything useful and we need to apply
Andreas' patch anyway, I don't think there's any benefit to apply this one.

Regards,

Anthony Liguori

>
> Regards,
> Andreas
>
> -- 
> SUSE LINUX Products GmbH, Maxfeldstr. 5, 90409 Nürnberg, Germany
> GF: Jeff Hawn, Jennifer Guild, Felix Imendörffer; HRB 16746 AG Nürnberg

Reply via email to