On 07/31/2012 06:34 PM, Peter Maydell wrote:
On 27 July 2012 20:29, Igor Mitsyanko <i.mitsya...@samsung.com> wrote:
Standard capacity cards SDSC use byte unit address while SDHC and SDXC Cards use
block unit address (512 bytes) when setting ERASE_START and ERASE_END with CMD32
and CMD33, we have to account for this.
Signed-off-by: Igor Mitsyanko <i.mitsya...@samsung.com>
---
hw/sd.c | 6 ++++--
1 files changed, 4 insertions(+), 2 deletions(-)
diff --git a/hw/sd.c b/hw/sd.c
index d0674d5..f7aa580 100644
--- a/hw/sd.c
+++ b/hw/sd.c
@@ -482,8 +482,10 @@ static void sd_erase(SDState *sd)
return;
}
- start = sd_addr_to_wpnum(sd->erase_start);
- end = sd_addr_to_wpnum(sd->erase_end);
+ start = sd_addr_to_wpnum(sd->ocr & (1 << 30) ?
+ (uint64_t)sd->erase_start * 512 : sd->erase_start);
+ end = sd_addr_to_wpnum(sd->ocr & (1 << 30) ?
+ (uint64_t)sd->erase_end * 512 : sd->erase_end);
I think this would be a little clearer phrased as:
uint64_t erase_start = sd->erase_start;
uint64_t erase_end = sd->erase_end;
[...]
if (extract32(sd->ocr, 30, 1)) {
/* High capacity memory card: erase units are 512 byte blocks */
erase_start *= 512;
erase_end *= 512;
}
start = sd_addr_to_wpnum(erase_start);
end = sd_addr_to_wpnum(erase_end);
(I don't insist on the extract32() if you don't like it, but I
would like to avoid the repeated inline ?: ops.)
-- PMM
I like it, I extensively use your new fancy extract/deposit api in my
local work.