STINNER Victor <victor.stin...@haypocalc.com> added the comment: TODO (maybe): Call the original signal handler to make tools like apport or ABRT able to catch segmentation faults.
> By the way, don't you want to handle SIGILL and SIGBUS too? Maybe. SIGILL is a very rare exception. To test it, should I send a SIGILL signal to the process? Or should I try to execute arbitrary CPU instructions? About SIGBUS: I don't know this signal. Is it used on Linux? If not, on which OS is it used? ---------- _______________________________________ Python tracker <rep...@bugs.python.org> <http://bugs.python.org/issue8863> _______________________________________ _______________________________________________ Python-bugs-list mailing list Unsubscribe: http://mail.python.org/mailman/options/python-bugs-list/archive%40mail-archive.com