STINNER Victor <vstin...@python.org> added the comment:

> command timed out: 1200 seconds without output running ['make', 
> 'buildbottest', 'TESTOPTS=-j2 -j4 ${BUILDBOT_TESTOPTS}', 'TESTPYTHONOPTS=', 
> 'TESTTIMEOUT=900'], attempting to kill

faulthandler is supposed to display the traceback where the test hangs, but for 
the main process, libregrtest uses a delay of timeout x 2 seconds:

            self.worker_timeout = self.ns.timeout * 1.5
            self.main_timeout = self.ns.timeout * 2.0

Here timeout=900 ("TESTTIMEOUT=900"), so main_timeout = 1800 seconds (30 
minutes), whereas buildbot timeout is 1200 seconds (20 minutes) :-(

In fact, main_timeout can be *way* shorter: the main process calls 
faulthandler.dump_traceback_later(self.main_timeout, exit=True) every 
max(PROGRESS_UPDATE, PROGRESS_MIN_TIME) seconds (or more often): every 30 
seconds (of more often).

So main_process could be max(PROGRESS_UPDATE, PROGRESS_MIN_TIME) x 2 = 1 
minute, instead of 30 minutes.

----------

_______________________________________
Python tracker <rep...@bugs.python.org>
<https://bugs.python.org/issue38190>
_______________________________________