Serhiy Storchaka added the comment:

I suppose this crash is caused by this code:

/*[clinic input]
zlib.Compress.flush

    self: self(type="compobject *")
    mode: int(c_default="Z_FINISH") = zlib.Z_FINISH
        One of the constants Z_SYNC_FLUSH, Z_FULL_FLUSH, Z_FINISH.
        If mode == Z_FINISH, the compressor object can no longer be used after
        calling the flush() method.  Otherwise, more data can still be 
compressed.
    /

Return a bytes object containing any remaining compressed data.
[clinic start generated code]*/

It was valid several days ago.

Therefore here are two bugs:

1. Argument Clinic should output a line number where it has encountered illegal 
expression.

2. It should accept zlib.Z_FINISH (Z_FINISH is exported constant in the zlib 
module).

----------

_______________________________________
Python tracker <rep...@bugs.python.org>
<http://bugs.python.org/issue20273>
_______________________________________