Hi pylons-discuss,
I followed the instructions in
http://pylonshq.com/docs/en/1.0/logging/#request-logging-with-paste-s-translogger
to add a logging filter to development.ini and then my unit tests
broke:
File "/home/nadav/Development/myproj/myproj/tests/__init__.py", line
29, in <module>
[pylons.test.pylonsapp.config['__file__']])
AttributeError: 'TransLogger' object has no attribute 'config'
After a little investigation, It turns out by adding the filter,
pylonsapp becomes the filter and not the app, so in an attempt to make
it work I changed tests/__init__.py from
SetupCommand('setup-
app').run([pylons.test.pylonsapp.config['__file__']])
to
SetupCommand('setup-
app').run([pylons.test.pylonsapp.application.config['__file__']])
(so it finds the real pylons app). Then, I got the following
exception:
File "/home/nadav/py26pylons/lib/python2.6/site-packages/
PasteScript-1.7.3-py2.6.egg/paste/script/appinstall.py", line 453, in
command
"The section %r is not the application (probably a filter). You
should add #section_name, where section_name is the section that
configures your application" % plain_section)
BadCommand: The section 'main' is not the application (probably a
filter). You should add #section_name, where section_name is the
section that configures your application
If I remove the TransLogger from development.ini it all works, but I
want it there. Is there any way to fix it? Can I make test.ini use
development.ini but override the TransLogger filter?
--