On Fri Jan 10, 2025 at 6:00 PM CET, Daniel Kral wrote: > From a user's perspective, the BTRFS single mode has been removed since > d85180e ("tui: rename raid levels 0/1 to align with GUI installer"). The > user can now only select at least the "RAID0" level, but if a user > selects any raid level with only one disk configured on the system, > BTRFS will be setup in 'single' mode instead of the chosen raid level. > > The TUI installer has a separate check for this, but the GUI installer > as well as the auto installer will silently fallback to single mode, > which could be confusing for and unwanted by the user. > > Therefore, remove the BTRFS single mode from being selected when > configuring disks in the GUI installer and during the installation in > general, which makes the auto installer fail if the wrong amount of > disks are selected for the specified raid level. This makes btrfs' raid > disk count validation align with the one from zfs. > > Signed-off-by: Daniel Kral <d.k...@proxmox.com>
Tested this patch with GUI, TUI and auto installer, whether they all now properly reject invalid configurations for each RAID mode. I.e. for RAID0 <1 disks, RAID1 <2 disks and RAID10 <4 disks. Tested each also with exactly one disk, of course. Please consider this patch: Tested-by: Christoph Heiss <c.he...@proxmox.com> Reviewed-by: Christoph Heiss <c.he...@proxmox.com> FWIW and completeness: `proxmox-auto-install-assistant validate-answer` does not (yet) check the filesystem configuration, but the auto-installer will still fail on invalid configuration as expected. Michael is working on improving the former, tho. > --- > > Discussion > > BTRFS didn't allow a single-disk RAID0 configuration before kernel 5.15 > and AFAIK also silently used the single profile for that case, but this > has changed since then. > > If we want users to still be able to create a BTRFS filesystem in single > mode (which seems very reasonable), I can do a v2 or followup to add a > "btrfs (single)" entry to the disk setup. I think it's fine as it currently is, i.e. we don't really need the extra single mode. Since it is supported to create single-disk RAID0 setups and doesn't result in a degraded state or similar, it is nice to have a) the simplicity of having one entry/filesystem type less and b) being consistent with the ZFS side of things on that matter. _______________________________________________ pve-devel mailing list pve-devel@lists.proxmox.com https://lists.proxmox.com/cgi-bin/mailman/listinfo/pve-devel