Hi guys,

I have Prometheus in HA mode - 4 nodes - Prometheus+Aletmanager on each. 
Everything works fine but very often I experience issue that an alert is 
firing again even the event is already resolved by alertmanager.

Below logs from example event(Chrony_Service_Down) recorded by alertmanager:

############################################################################################################
(1) Jan 10 10:48:48 prometheus-01 alertmanager[1213219]: 
ts=2023-01-10T10:48:48.746Z caller=dispatch.go:165 level=debug 
component=dispatcher msg="Received alert" 
alert=Chrony_Service_Down[d8c020a][active]

(2) Jan 10 10:49:19 prometheus-01 alertmanager[1213219]: 
ts=2023-01-10T10:49:19.460Z caller=nflog.go:553 level=debug component=nflog 
msg="gossiping new entry" 
entry="entry:<group_key:\"{}/{severity=\\\"page\\\"}:{alertname=\\\"Chrony_Service_Down\\\",
 
datacenter=\\\"dc01\\\", exporter=\\\"node\\\", 
fqdn=\\\"server.example.com\\\", instance=\\\"server.example.com\\\", 
job=\\\"node\\\", monitoring_infra=\\\"prometheus-mon\\\", 
puppet_certname=\\\"server.example.com\\\", service=\\\"chrony\\\", 
severity=\\\"page\\\"}\" receiver:<group_name:\"opsgenie\" 
integration:\"opsgenie\" > timestamp:<seconds:1673347759 nanos:262824014 > 
firing_alerts:10151928354614242630 > expires_at:<seconds:1673779759 
nanos:262824014 > "

(3) Jan 10 10:50:48 prometheus-01 alertmanager[1213219]: 
ts=2023-01-10T10:50:48.745Z caller=dispatch.go:165 level=debug 
component=dispatcher msg="Received alert" 
alert=Chrony_Service_Down[d8c020a][resolved]

(4) Jan 10 10:51:29 prometheus-01 alertmanager[1213219]: 
ts=2023-01-10T10:51:29.183Z caller=nflog.go:553 level=debug component=nflog 
msg="gossiping new entry" 
entry="entry:<group_key:\"{}/{severity=\\\"page\\\"}:{alertname=\\\"Chrony_Service_Down\\\",
 
datacenter=\\\"dc01\\\", exporter=\\\"node\\\", 
fqdn=\\\"server.example.com\\\", instance=\\\"server.example.com\\\", 
job=\\\"node\\\", monitoring_infra=\\\"prometheus-mon\\\", 
puppet_certname=\\\"server.example.com\\\", service=\\\"chrony\\\", 
severity=\\\"page\\\"}\" receiver:<group_name:\"opsgenie\" 
integration:\"opsgenie\" > timestamp:<seconds:1673347888 nanos:897562679 > 
resolved_alerts:10151928354614242630 > expires_at:<seconds:1673779888 
nanos:897562679 > "

(5) Jan 10 10:51:49 prometheus-01 alertmanager[1213219]: 
ts=2023-01-10T10:51:49.745Z caller=nflog.go:553 level=debug component=nflog 
msg="gossiping new entry" 
entry="entry:<group_key:\"{}/{severity=\\\"page\\\"}:{alertname=\\\"Chrony_Service_Down\\\",
 
datacenter=\\\"dc01\\\", exporter=\\\"node\\\", 
fqdn=\\\"server.example.com\\\", instance=\\\"server.example.com\\\", 
job=\\\"node\\\", monitoring_infra=\\\"prometheus-mon\\\", 
puppet_certname=\\\"server.example.com\\\", service=\\\"chrony\\\", 
severity=\\\"page\\\"}\" receiver:<group_name:\"opsgenie\" 
integration:\"opsgenie\" > timestamp:<seconds:1673347909 nanos:649205670 > 
firing_alerts:10151928354614242630 > expires_at:<seconds:1673779909 
nanos:649205670 > "

(6) Jan 10 10:51:59 prometheus-01 alertmanager[1213219]: 
ts=2023-01-10T10:51:59.312Z caller=nflog.go:553 level=debug component=nflog 
msg="gossiping new entry" 
entry="entry:<group_key:\"{}/{severity=\\\"page\\\"}:{alertname=\\\"Chrony_Service_Down\\\",
 
datacenter=\\\"dc01\\\", exporter=\\\"node\\\", 
fqdn=\\\"server.example.com\\\", instance=\\\"server.example.com\\\", 
job=\\\"node\\\", monitoring_infra=\\\"prometheus-mon\\\", 
puppet_certname=\\\"server.example.com\\\", service=\\\"chrony\\\", 
severity=\\\"page\\\"}\" receiver:<group_name:\"opsgenie\" 
integration:\"opsgenie\" > timestamp:<seconds:1673347919 nanos:137020780 > 
resolved_alerts:10151928354614242630 > expires_at:<seconds:1673779919 
nanos:137020780 > "

(7) Jan 10 10:54:58 prometheus-01 alertmanager[1213219]: 
ts=2023-01-10T10:54:58.744Z caller=dispatch.go:165 level=debug 
component=dispatcher msg="Received alert" 
alert=Chrony_Service_Down[d8c020a][resolved]
#############################################################################################################

Interesting is line number 5 (Jan 10 10:51:49) where alertmanager fired 
alert second time even minute ago (Jan 10 10:50:48) the alert was marked as 
resolved.
Such behavior generates duplicate alert in our system which is quite 
annoying in our scale.

What is worth to mention:
- For test purpose the event is scrapped by 4 Promethues servers(default) 
but alert rule is evaluated by one Promethues.
- The event occurres only once so there is no flapping which might cause 
another alert firing.

Thanks

-- 
You received this message because you are subscribed to the Google Groups 
"Prometheus Users" group.
To unsubscribe from this group and stop receiving emails from it, send an email 
to [email protected].
To view this discussion on the web visit 
https://groups.google.com/d/msgid/prometheus-users/a3ced99d-58f8-4275-a478-3d2ab884b764n%40googlegroups.com.

Reply via email to