Kent Belan wrote on 2011-11-10: 
>  Hello Tracy,
>  
>  I rebuilt the entire project but that did not change the controls on the
>  forms to the new version.
>  
>  I opened the form.scx file and found the ctGrid OLE control, but not sure
>  what field should be changed ?
>  
>  It looks like the OLE field contains the actual object, and OLE2 contains
>  the path to the OCX file.
>  
>  I checked that the OCX in the DBI\Components folder is the new version,
but
>  the form still shows the old version.
>  
>  I am guessing that I need to change the OLE field ?
>  
>  Thanks,
>  Kent
>  

Kent,

You're guessing right. 
Create a form (vfp base form is fine) and add the ole control to it.

If memory serves, this was my method. I only had a couple of places to do
it.
As always, source control and a good back up are recommended. <smile>

Use the newly created form
Find the ole control
SCATTER FIELDS ole, ole2 MEMO NAME ole
Use the existing form
Find the ole control
GATHER NAME ole MEMO



Tracy Pearson
PowerChurch Software


_______________________________________________
Post Messages to: ProFox@leafe.com
Subscription Maintenance: http://leafe.com/mailman/listinfo/profox
OT-free version of this list: http://leafe.com/mailman/listinfo/profoxtech
Searchable Archive: http://leafe.com/archives/search/profox
This message: 
http://leafe.com/archives/byMID/profox/000501cc9fc4$03a89cd0$0af9d670$@powerchurch.com
** All postings, unless explicitly stated otherwise, are the opinions of the 
author, and do not constitute legal or medical advice. This statement is added 
to the messages for those lawyers who are too stupid to see the obvious.

Reply via email to