Hello, We are currently using exporting Netflow data to multiple Netflow collectors using the tee plugin along with nfacctd. The problem is that we are sampling our flows, and some collectors don't offer the possibility to correct the values.
I saw that nfacctd had some parameters that could correct the data (like renormalize) and I would like to use it to correct my sampled Netflow before exporting it with the tee plugin, but I still get the sampled values. We are using Netflow v9 and the sampling value is not sent by the router. Here is an example of the .conf file I use for nfacctd : nfacctd_port: 2100 nfacctd_ip: 0.0.0.0 nfacctd_renormalize: true nfacctd_ext_sampling_rate: 1024 ! plugins: tee[br01] tee_receivers[br01]: /var/pmacct/tee_br01.lst ! !pre_tag_map: /path/to/pretag.map ! plugin_buffer_size: 10240 plugin_pipe_size: 1024000 nfacctd_pipe_size: 1024000 Do you have any suggestion about it ? Many thanks _______________________________________________ pmacct-discussion mailing list http://www.pmacct.net/#mailinglists