Hi Daniel, It is not, but implementation would not be a biggie. Totally open to it. Can you just say what you would like to get implemented? Something a-la IPFIX information elements flowStartSeconds (#150), flowEndSeconds (#151), flowStartMilliseconds (#152), flowStartMilliseconds (#153) in place of "legacy" flowStartSysUpTime (#22), flowStartSysUpTime (#21)? Or you rather thing to something different? Let me know.
Cheers, Paolo On Fri, Aug 12, 2011 at 03:45:22PM +0200, Daniel Aschwanden wrote: > -----BEGIN PGP SIGNED MESSAGE----- > Hash: SHA256 > > Hi all, > > I've just noticed that pmacctd with the netflow plugin is not exporting > any flow start and flow end times with millisecond resolution. Is this > behavior configurable somehow? > > Any advice is appreciated! > > Regards, > > Dani Aschwanden > -----BEGIN PGP SIGNATURE----- > Version: GnuPG v1.4.10 (GNU/Linux) > Comment: Using GnuPG with Mozilla - http://enigmail.mozdev.org/ > > iF4EAREIAAYFAk5FLnIACgkQxIzmH53Qg6GwCwD/ePfV/OeGK/zeOH9ewFhsvSYD > 4wqZOz707lJTXxe7wWMA/jSm7d+GwnVxQunInSjVNTnZ4PHpRtzty7I+HMwgl4sp > =Vmtl > -----END PGP SIGNATURE----- > > _______________________________________________ > pmacct-discussion mailing list > http://www.pmacct.net/#mailinglists _______________________________________________ pmacct-discussion mailing list http://www.pmacct.net/#mailinglists