FYI, this has been committed by Tom. ---------------------------------------------------------------------------
ITAGAKI Takahiro wrote: > The GucContext of log_autovacuum is PGC_BACKEND in the CVS HEAD, > but should it be PGC_SIGHUP? We cannot modify the variable on-the-fly > because the parameter is used only by autovacuum worker processes. > The similar variables, like autovacuum_vacuum_scale_factor, are > defined as PGC_SIGHUP. > > > Index: src/backend/utils/misc/guc.c > =================================================================== > --- src/backend/utils/misc/guc.c (head) > +++ src/backend/utils/misc/guc.c (working copy) > @@ -1552,7 +1552,7 @@ > }, > > { > - {"log_autovacuum", PGC_BACKEND, LOGGING_WHAT, > + {"log_autovacuum", PGC_SIGHUP, LOGGING_WHAT, > gettext_noop("Sets the minimum execution time above > which autovacuum actions " > "will be logged."), > gettext_noop("Zero prints all actions. The default is > -1 (turning this feature off)."), > > Regards, > --- > ITAGAKI Takahiro > NTT Open Source Software Center > > > ---------------------------(end of broadcast)--------------------------- > TIP 4: Have you searched our list archives? > > http://archives.postgresql.org -- Bruce Momjian <[EMAIL PROTECTED]> http://momjian.us EnterpriseDB http://www.enterprisedb.com + If your life is a hard drive, Christ can be your backup. + ---------------------------(end of broadcast)--------------------------- TIP 2: Don't 'kill -9' the postmaster