I've noticed that if for example the autovacuum process dies (such as with a kill -9 when testing my new shared mem implementation), only autovac and bgwriter are restarted. The stats collector is terminated, but not restarted. (Same goes for a regular backend, and not just autovac)
Is there a reason for this, or is it a bug? //Magnus ---------------------------(end of broadcast)--------------------------- TIP 1: if posting/reading through Usenet, please send an appropriate subscribe-nomail command to [EMAIL PROTECTED] so that your message can get through to the mailing list cleanly