Simon Riggs <[EMAIL PROTECTED]> writes: > On Wed, 2006-06-07 at 15:32 -0400, Tom Lane wrote: >> I propose we revert this patch and think about an interrupt-driven >> sampling method instead.
> I don't have much more faith in crazy scheme No.2 either. (Mine or > yours...) > Can we just have an option to avoid the timing altogether, please? I > don't want to have long discussions about instrumentation, I just want a > reasonably useful EXPLAIN ANALYZE in a reasonable amount of time - one > that we never, ever have to doubt whether the sampling works correctly > on a Miasmic-367 with HyperKooling. Frankly, I think the pre-existing version of EXPLAIN ANALYZE is fine. People have been hyperventilating about the timing overhead but I think that it's perfectly acceptable as-is. Certainly the removal of timing is not going to convert an intolerable EXPLAIN ANALYZE runtime into an acceptable one; what it *is* likely to do is let you be misled about which part of the query is the problem. regards, tom lane ---------------------------(end of broadcast)--------------------------- TIP 5: don't forget to increase your free space map settings