Tom Lane escreveu: > (1) Windows compatibility? > Yes. > (2) What happens if the command takes a significant amount of time to > execute? We can't afford to have the log collector blocked. > You're right. We can't have that command in the same process because DBAs could have high values for log_rotation_* parameters or resources could become unavailable. :( One idea is to have another process (logger worker) to execute it. Also we need to store the logfiles that were already rotated.
> (3) What do you intend those %p and %f symbols to signify? > %p and %f are relative log path and log filename, respectively. -- Euler Taveira de Oliveira http://www.timbira.com/ -- Sent via pgsql-hackers mailing list (pgsql-hackers@postgresql.org) To make changes to your subscription: http://www.postgresql.org/mailpref/pgsql-hackers