Tom Lane escreveu:
> (1) Windows compatibility?
> 
Yes.

> (2) What happens if the command takes a significant amount of time to
> execute?  We can't afford to have the log collector blocked.
> 
You're right. We can't have that command in the same process because DBAs
could have high values for log_rotation_* parameters or resources could become
unavailable. :( One idea is to have another process (logger worker) to execute
it. Also we need to store the logfiles that were already rotated.

> (3) What do you intend those %p and %f symbols to signify?
> 
%p and %f are relative log path and log filename, respectively.


-- 
  Euler Taveira de Oliveira
  http://www.timbira.com/


-- 
Sent via pgsql-hackers mailing list (pgsql-hackers@postgresql.org)
To make changes to your subscription:
http://www.postgresql.org/mailpref/pgsql-hackers

Reply via email to