On Fri, 2 Jul 2021 at 19:48, Ranier Vilela <ranier...@gmail.com> wrote:
>
> If you allow me a small suggestion.
> Move the initializations of the variable tmp_var to after check if the 
> function can run.
> Saves some cycles, when not running.
>

OK, thanks. I agree, on grounds of neatness and consistency with
nearby code, so I've done it that way.

Note, however, that it won't make any difference to performance in the
way that you're suggesting -- elog() in Postgres is used for "should
never happen, unless there's a software bug" errors, rather than, say,
"might happen for certain invalid inputs" errors, so init_var() should
always be called in these functions.

Regards,
Dean


Reply via email to