On Tue, Jun 08, 2021 at 06:59:04PM +0900, Kyotaro Horiguchi wrote: > The cause is that the time unit is changed to usec but the patch > forgot to convert agg_interval into the same unit in doLog. I tempted > to change it into pg_time_usec_t but it seems that it is better that > the unit is same with other similar variables like duration.
As the option remains in seconds, I think that it is simpler to keep it as an int, and do the conversion where need be. It would be good to document that agg_interval is in seconds where the variable is defined. - while (agg->start_time + agg_interval <= now) + while (agg->start_time + agg_interval * 1000000 <= now) In need of a cast with (int64), no? The other things are "progress" and "duration". These look correctly handled to me. -- Michael