On Tue, Jan 26, 2021 at 12:54 PM Fujii Masao <masao.fu...@oss.nttdata.com> wrote: > On 2021/01/26 16:05, Tom Lane wrote: > > Fujii Masao <masao.fu...@oss.nttdata.com> writes: > >> Thanks for the review! I fixed them and pushed the patch! > > > > Buildfarm is very not happy ... > > Yes.... I'm investigating that. > > -- Return false as connections are still in use, warnings are issued. > SELECT postgres_fdw_disconnect_all(); > -WARNING: cannot close dropped server connection because it is still in use > -WARNING: cannot close connection for server "loopback" because it is still > in use > WARNING: cannot close connection for server "loopback2" because it is > still in use > +WARNING: cannot close connection for server "loopback" because it is still > in use > +WARNING: cannot close dropped server connection because it is still in use > > The cause of the regression test failure is that the order of warning messages > is not stable. So I'm thinking to set client_min_messages to ERROR temporarily > when doing the above test.
Looks like we do suppress warnings/notices by setting client_min_messages to ERROR/WARNING. For instance, "suppress warning that depends on wal_level" and "Suppress NOTICE messages when users/groups don't exist". With Regards, Bharath Rupireddy. EnterpriseDB: http://www.enterprisedb.com