Hi all,

Interesting bug!

The end-position calculation in v8 looks correct to me.

The end of the switch record is already computed in
ReserveXLogSwitch(), before the reservation is extended to the segment
boundary. Could we keep that value rather than reconstruct it later?

PFA an alternative based on v8, with the existing test included. It
separates EndPos from ReservedEndPos. That needs a little more
refactoring, but each variable keeps one meaning throughout
XLogInsertRecord(), which I find easier to follow. WDYT?
It's only an idea on how to do less bugs in future, I'm not wedded to
this refactoring.

Perhaps, for backpatching, v8 is preferable because the change is smaller.

Thank you!


Best regards, Andrey Borodin.

Attachment: v9-0001-Keep-WAL-switch-record-and-reservation-ends-distinct.patch
Description: Binary data