On 2025-Nov-04, Álvaro Herrera wrote: > 2025-11-04 16:44:47.792 CET [2118443][autovacuum worker][108/6:0] ERROR: > canceling autovacuum task > 2025-11-04 16:44:47.792 CET [2118443][autovacuum worker][108/6:0] CONTEXT: > processing work entry for relation "postgres.public.brin_packdate_idx" > 2025-11-04 16:44:47.810 CET [2118078][autovacuum worker][103/10:0] LOG: > process 2118078 acquired ShareUpdateExclusiveLock on relation 16436 of > database 5 after 1414.103 ms
> ==2118443== VALGRINDERROR-BEGIN > ==2118443== Invalid read of size 8 > ==2118443== at 0x4634F39: PopActiveSnapshot (snapmgr.c:777) > ==2118443== by 0x43F693F: do_autovacuum (autovacuum.c:2561) > ==2118443== by 0x43F6E2B: AutoVacWorkerMain (autovacuum.c:1604) Ah, the problem is that perform_work_item() pushes an active snapshot before calling the BRIN function, but because of the error, we terminate the transaction before returning, so when we try to Pop that snapshot, it doesn't exist anymore. Other ways for this to happen would be an autovacuum worker trying to run an item for a dropped table (the "goto deleted2" case). Hmm ... -- Álvaro Herrera PostgreSQL Developer — https://www.EnterpriseDB.com/