Hi,

On 2018-07-10 06:41:32 +0500, Andrey V. Lepikhov wrote:
> This functionality is needed in practice when we have to determine a
> recovery time of specific backup.

What do you mean by "recovery time of specific backup"?


> This code developed in compatibility with WAL segments, which do not have a
> timestamp in a XLOG_BACKUP_END record.

I don't understand what "compatibility with WAL segments" could mean?
And how are WAL segments related to "XLOG_BACKUP_END record", except as
to how every WAL record is related? Are you thinking about the switch
records?

Greetings,

Andres Freund