On Wed, Sep 20, 2023 at 12:12 PM Amit Kapila <amit.kapil...@gmail.com> wrote:
>
> On Wed, Sep 20, 2023 at 11:51 AM Dilip Kumar <dilipbal...@gmail.com> wrote:
> >
> > On Wed, Sep 20, 2023 at 11:00 AM Hayato Kuroda (Fujitsu)
> > <kuroda.hay...@fujitsu.com> wrote:
> > >
> > > Dear Amit,
> > >
> > > Thank you for reviewing! PSA new version. In this version I ran pgindent 
> > > again.
> > >
> >
> > + /*
> > + * There is a possibility that following records may be generated
> > + * during the upgrade.
> > + */
> > + if (!CHECK_WAL_RECORD(rmid, info, RM_XLOG_ID, XLOG_CHECKPOINT_SHUTDOWN) &&
> > + !CHECK_WAL_RECORD(rmid, info, RM_XLOG_ID, XLOG_CHECKPOINT_ONLINE) &&
> > + !CHECK_WAL_RECORD(rmid, info, RM_XLOG_ID, XLOG_SWITCH) &&
> > + !CHECK_WAL_RECORD(rmid, info, RM_XLOG_ID, XLOG_FPI_FOR_HINT) &&
> > + !CHECK_WAL_RECORD(rmid, info, RM_XLOG_ID, XLOG_PARAMETER_CHANGE) &&
> > + !CHECK_WAL_RECORD(rmid, info, RM_STANDBY_ID, XLOG_RUNNING_XACTS) &&
> > + !CHECK_WAL_RECORD(rmid, info, RM_HEAP2_ID, XLOG_HEAP2_PRUNE))
> > + is_valid = false;
> > +
> > + CHECK_FOR_INTERRUPTS();
> >
> > Just wondering why XLOG_HEAP2_VACUUM or other vacuum-related commands
> > can not occur during the upgrade?
> >
>
> Because autovacuum is disabled during upgrade. See comment: "Use -b to
> disable autovacuum" in start_postmaster().

Okay got it, thanks.

-- 