On Thursday 09 October 2003 08:10, CSN wrote:
> Is there a way to have p/k sequences get automatically
> set to max(id)+1 after COPY's like the following?
>
> copy table1 (id,name) from stdin;
> 1 abc
> 2 def
> 3 fhi
> \.

Not really - if you don't use the sequence it keeps its value. If you look at 
pg_dump it issues an explicit setval() after a copy.

I'm not sure you can even work around it with a BEFORE trigger to check and 
update the sequence, the nextval() call will probably be processed before the 
trigger gets called (haven't checked). In any case, performance would be a 
bit poor.

Is there any reason why you're supplying your own id values when you already 
have a sequence?

-- 
  Richard Huxton