The following bug has been logged online: Bug reference: 1748 Logged by: Greg Steffensen Email address: [EMAIL PROTECTED] PostgreSQL version: 8.02 Operating system: Gentoo Linux Description: Unique contraints cannot be added to long text fields Details:
I'm storing SVG files, which can be many kilobytes long, in a text field. When I try to add a unique contraint to that field, or try to add a row to a table that already has had the unique contraint applied, I get errors like the following: ERROR: index row requires 15528 bytes, maximum size is 8191 Evidently, the unique constraint creates an index, but the index can't handle large field sizes. ---------------------------(end of broadcast)--------------------------- TIP 3: if posting/reading through Usenet, please send an appropriate subscribe-nomail command to [EMAIL PROTECTED] so that your message can get through to the mailing list cleanly