Bruce Momjian <pgman@candle.pha.pa.us> writes: > Tom Lane wrote: >> I don't have a problem with removing it as a writable option ... but >> I'm thinking we should leave it as a read-only GUC parameter (like >> the several others we have already). Otherwise we'll need to add some >> other method of finding out whether the collector is running.
> Why would a user care? luser> It's not collecting statistics! us> Is the collector running? luser> How should I know? us> er ... If we don't have a way to check this, we'll regret it soon enough... now maybe a GUC setting isn't the optimal way, but I think we need *some* way besides ps. ps doesn't work remotely and I think there's no simple equivalent under Windows either. regards, tom lane ---------------------------(end of broadcast)--------------------------- TIP 9: the planner will ignore your desire to choose an index scan if your joining column's datatypes do not match