Servers: Sun Fire X4240 (both servers)
Network: 1Gbps Ethernet
Disk: Intel X25-E 32GB SLC 

Attempt 1:

server1# zpool create X25E c1t15d0
server1# zfs set sharenfs=rw X25E
server1# chmod a+w /X25E

server2# /bin/time gtar zxf /var/tmp/emacs-22.3.tar.gz
real     1:21.5
user        1.4
sys         2.0

+ Plenty of SCSI errors that I mentioned in another thread:

Jul  7 23:22:38 merope  Error for Command: write                   Error Level: 
Retryable
Jul  7 23:22:38 merope scsi:    Requested Block: 98608                     
Error Block: 98608
Jul  7 23:22:38 merope scsi:    Vendor: ATA                                
Serial Number: CVEM849300BM
Jul  7 23:22:38 merope scsi:    Sense Key: Unit Attention
Jul  7 23:22:38 merope scsi:    ASC: 0x29 (power on, reset, or bus reset 
occurred), ASCQ: 0x0, FRU: 



Attempt 2:

server1# format (make two partitions on that SSD disk, s0=4G, s1=16G)
server1# zpool create X25E c1t15d0s1
+same commands above

server2# /bin/time gtar zxf /var/tmp/emacs-22.3.tar.gz

real       35.7
user        1.4
sys         2.0

Same SCSI errors on the console of server1...

Hmm...



Attempt 3:

server1# metainit d0 c1t15d0s0
server1# metainit d1 c1t15d0s1
server1# zpool create X25E /dev/md/dsk/d1
+same commands

server2# /bin/time gtar zxf /var/tmp/emacs-22.3.tar.gz

real       11.7
user        1.4
sys         2.0


*No* SCSI errors this time. Flawless execution of all commands...


Attempt 4 (just add a slog to the same zpool):

server1# zpool add X25E log /dev/md/dsk/d0

server2# /bin/time gtar zxf /var/tmp/emacs-22.3.tar.gz

real       11.2
user        1.4
sys         1.9

(No SCSI errors here either)
-- 
This message posted from opensolaris.org
_______________________________________________
perf-discuss mailing list
perf-discuss@opensolaris.org

Reply via email to