Hi Lejun,
  Instead of adding a new view, I am wondering if it makes more sense to add 
the information from the wakeup probe to the individual process view (the rows 
which display sleep or lwp_park or cond_wait etc.), unless the process view 
becomes cluttered of course. This way we will have all the information in the 
same place.
  I think, yes, you can get the timing from (wakeup - off-cpu) to calculate the 
amount of wait-time.

-Krish
-- 