Are you sure your cluster hostnames are ok? get_node_name: Could not obtain a node name for corosync nodeid 2
2015-04-24 17:09 GMT+02:00 Patrick Zwahlen <p...@navixia.com>: > Hi, > > I'm running a CentOS 7.0 2-nodes cluster providing iSCSI/SAN features. In > order to upgrade to CentOS 7.1, I'm testing the whole process in VMs and it > fails. I've now stripped my config down to a pair of DRBD MS with IPADDR2 > (cluster.cfg) attached. > > From a running cluster, here are the steps (I'm upgrading node san2): > - put node san2 in standby > - stop/disable pacemaker on san2 > - stop/disable corosync on san2 > - update san2 to CentOS 7.1 (pacemaker 1.1.10-32.el7_0.1 -> 1.1.12-22.el7_1.1) > - reboot san2 > - enable/start corosync on san2. It looks good, rings are fine in > "corosync-cfgtool-s") > - enable/start pacemaker on san2 > > I can see the following in the logs: > > /var/log/messages (attached, line #57) > ================= > Apr 24 16:18:26 san2 crmd[11759]: notice: erase_xpath_callback: Deletion of > "//node_state[@uname='san2.local']/transient_attributes": Application of an > update diff failed (rc=-206) > > /var/log/pacemaker.log (attached, starting from line #292) > ====================== > Apr 24 16:18:26 [11754] san2.local cib: info: xml_apply_patchset: > v1 digest mis-match: expected 428c0eb4cd80a4c1ee19b627f6876abd, calculated > ffb5456991bd4ed9e5a7774f49e8259d > Apr 24 16:18:26 [11754] san2.local cib: info: __xml_diff_object: > Moved node_state@id (0 -> 6) > Apr 24 16:18:26 [11754] san2.local cib: info: __xml_diff_object: > Moved node_state@uname (1 -> 0) > Apr 24 16:18:26 [11759] san2.local crmd: notice: > erase_xpath_callback: Deletion of > "//node_state[@uname='san2.local']/transient_attributes": Application of an > update diff failed (rc=-206) > Apr 24 16:18:26 [11754] san2.local cib: info: send_sync_request: > Requesting re-sync from peer > Apr 24 16:18:26 [11754] san2.local cib: notice: > cib_server_process_diff: Not applying diff 0.0.14 -> 0.46.15 (sync in > progress) > Apr 24 16:18:26 [11754] san2.local cib: notice: > cib_server_process_diff: Not applying diff 0.0.15 -> 0.46.16 (sync in > progress) > Apr 24 16:18:26 [11754] san2.local cib: notice: > cib_server_process_diff: Not applying diff 0.0.16 -> 0.46.17 (sync in > progress) > > Google doesn't help me in figuring out what might be wrong. > > Config was generated with crmsh-2.1-1.4 is that can have an impact. > > Any hint would be highly appreciated. > > Cheers, Patrick > > NOTE: I have kernel modules (scst/zfs) that require reboots when upgrading, > so I cannot upgrade both nodes while in unmanaged state. I really need to > upgrade one node after the other. > > > ************************************************************************************** > This email and any files transmitted with it are confidential and > intended solely for the use of the individual or entity to whom they > are addressed. If you have received this email in error please notify > the system manager. "postmas...@navixia.com" Navixia SA > ************************************************************************************** > > _______________________________________________ > Pacemaker mailing list: Pacemaker@oss.clusterlabs.org > http://oss.clusterlabs.org/mailman/listinfo/pacemaker > > Project Home: http://www.clusterlabs.org > Getting started: http://www.clusterlabs.org/doc/Cluster_from_Scratch.pdf > Bugs: http://bugs.clusterlabs.org > -- esta es mi vida e me la vivo hasta que dios quiera _______________________________________________ Pacemaker mailing list: Pacemaker@oss.clusterlabs.org http://oss.clusterlabs.org/mailman/listinfo/pacemaker Project Home: http://www.clusterlabs.org Getting started: http://www.clusterlabs.org/doc/Cluster_from_Scratch.pdf Bugs: http://bugs.clusterlabs.org