Are you sure your cluster hostnames are ok?

get_node_name: Could not obtain a node name for corosync nodeid 2

2015-04-24 17:09 GMT+02:00 Patrick Zwahlen <p...@navixia.com>:
> Hi,
>
> I'm running a CentOS 7.0 2-nodes cluster providing iSCSI/SAN features. In 
> order to upgrade to CentOS 7.1, I'm testing the whole process in VMs and it 
> fails. I've now stripped my config down to a pair of DRBD MS with IPADDR2 
> (cluster.cfg) attached.
>
> From a running cluster, here are the steps (I'm upgrading node san2):
> - put node san2 in standby
> - stop/disable pacemaker on san2
> - stop/disable corosync on san2
> - update san2 to CentOS 7.1 (pacemaker 1.1.10-32.el7_0.1 -> 1.1.12-22.el7_1.1)
> - reboot san2
> - enable/start corosync on san2. It looks good, rings are fine in 
> "corosync-cfgtool-s")
> - enable/start pacemaker on san2
>
> I can see the following in the logs:
>
> /var/log/messages (attached, line #57)
> =================
> Apr 24 16:18:26 san2 crmd[11759]: notice: erase_xpath_callback: Deletion of 
> "//node_state[@uname='san2.local']/transient_attributes": Application of an 
> update diff failed (rc=-206)
>
> /var/log/pacemaker.log (attached, starting from line #292)
> ======================
> Apr 24 16:18:26 [11754] san2.local        cib:     info: xml_apply_patchset:  
>   v1 digest mis-match: expected 428c0eb4cd80a4c1ee19b627f6876abd, calculated 
> ffb5456991bd4ed9e5a7774f49e8259d
> Apr 24 16:18:26 [11754] san2.local        cib:     info: __xml_diff_object:   
>   Moved node_state@id (0 -> 6)
> Apr 24 16:18:26 [11754] san2.local        cib:     info: __xml_diff_object:   
>   Moved node_state@uname (1 -> 0)
> Apr 24 16:18:26 [11759] san2.local       crmd:   notice: 
> erase_xpath_callback:  Deletion of 
> "//node_state[@uname='san2.local']/transient_attributes": Application of an 
> update diff failed (rc=-206)
> Apr 24 16:18:26 [11754] san2.local        cib:     info: send_sync_request:   
>   Requesting re-sync from peer
> Apr 24 16:18:26 [11754] san2.local        cib:   notice: 
> cib_server_process_diff:       Not applying diff 0.0.14 -> 0.46.15 (sync in 
> progress)
> Apr 24 16:18:26 [11754] san2.local        cib:   notice: 
> cib_server_process_diff:       Not applying diff 0.0.15 -> 0.46.16 (sync in 
> progress)
> Apr 24 16:18:26 [11754] san2.local        cib:   notice: 
> cib_server_process_diff:       Not applying diff 0.0.16 -> 0.46.17 (sync in 
> progress)
>
> Google doesn't help me in figuring out what might be wrong.
>
> Config was generated with crmsh-2.1-1.4 is that can have an impact.
>
> Any hint would be highly appreciated.
>
> Cheers, Patrick
>
> NOTE: I have kernel modules (scst/zfs) that require reboots when upgrading, 
> so I cannot upgrade both nodes while in unmanaged state. I really need to 
> upgrade one node after the other.
>
>
> **************************************************************************************
> This email and any files transmitted with it are confidential and
> intended solely for the use of the individual or entity to whom they
> are addressed. If you have received this email in error please notify
> the system manager. "postmas...@navixia.com"      Navixia SA
> **************************************************************************************
>
> _______________________________________________
> Pacemaker mailing list: Pacemaker@oss.clusterlabs.org
> http://oss.clusterlabs.org/mailman/listinfo/pacemaker
>
> Project Home: http://www.clusterlabs.org
> Getting started: http://www.clusterlabs.org/doc/Cluster_from_Scratch.pdf
> Bugs: http://bugs.clusterlabs.org
>



-- 
esta es mi vida e me la vivo hasta que dios quiera

_______________________________________________
Pacemaker mailing list: Pacemaker@oss.clusterlabs.org
http://oss.clusterlabs.org/mailman/listinfo/pacemaker

Project Home: http://www.clusterlabs.org
Getting started: http://www.clusterlabs.org/doc/Cluster_from_Scratch.pdf
Bugs: http://bugs.clusterlabs.org

Reply via email to