Apologies for double post. In my initial post, I forgot to set the subject properly.
Hello List, I am new here. I worked with Linux HA during 2006-2008, went in HPC direction, and came back to HA a month ago. Realized that a lot has changed. My setup: Two KVM machines vdb1 (192.168.122.11), vdb2 (192.168.122.12) ClusterIP: 192.168.122.10 Fedora 19 (64 bit). PCS, CoroSync, PaceMaker, DRBD Note: I use the names node1 and node2 for vdb1 and vdb2 for explanations. I am trying to setup a test cluster, using http://clusterlabs.org/doc/en-US/Pacemaker/1.1-pcs/html/Clusters_from_Scratch/_configure_the_cluster_for_drbd.html First, the status: [root@vdb1 drbd.d]# pcs status Cluster name: MySQLCluster Last updated: Tue Nov 26 14:05:33 2013 Last change: Mon Nov 25 17:25:59 2013 via crm_resource on vdb2.example.com Stack: corosync Current DC: vdb1.example.com (1) - partition with quorum Version: 1.1.9-3.fc19-781a388 2 Nodes configured, unknown expected votes 2 Resources configured. Online: [ vdb1.example.com vdb2.example.com ] Full list of resources: ClusterIP (ocf::heartbeat:IPaddr2): Started vdb1.example.com Apache (ocf::heartbeat:apache): Started vdb1.example.com [root@vdb1 drbd.d]# My DRBD disks are: [root@vdb1 drbd.d]# drbd-overview 1:MySQLDisk/0 Connected Secondary/Secondary UpToDate/UpToDate C r----- 2:ApacheDisk/0 Connected Secondary/Secondary UpToDate/UpToDate C r----- [root@vdb1 drbd.d]# Now, the guide suggests creating a small config file, define the new resources in that, and then push that in CIB. Extract from the guide: # pcs cluster cib drbd_cfg # pcs -f drbd_cfg resource create WebData ocf:linbit:drbd \ drbd_resource=wwwdata op monitor interval=60s # pcs -f drbd_cfg resource master WebDataClone WebData \ master-max=1 master-node-max=1 clone-max=2 clone-node-max=1 \ notify=true I decided to execute the commands (manually), without using the config file method, as: # pcs resource create p_ApacheDisk ocf:linbit:drbd \ > drbd_resource=ApacheDisk op monitor interval=60s # pcs resource master MasterApacheDisk p_ApacheDisk \ > master-max=1 master-node-max=1 clone-max=2 clone-node-max=1 \ > notify=true (I changed the names of resources a bit) I get the following errors: [root@vdb2 ~]# pcs resource create p_ApacheDisk ocf:linbit:drbd \ > drbd_resource=ApacheDisk op monitor interval=60s [root@vdb2 ~]# pcs status Cluster name: MySQLCluster Last updated: Wed Nov 27 11:50:35 2013 Last change: Wed Nov 27 11:49:36 2013 via cibadmin on vdb2.example.com Stack: corosync Current DC: vdb1.example.com (1) - partition with quorum Version: 1.1.9-3.fc19-781a388 2 Nodes configured, unknown expected votes 3 Resources configured. Online: [ vdb1.example.com vdb2.example.com ] Full list of resources: ClusterIP (ocf::heartbeat:IPaddr2): Started vdb1.example.com Apache (ocf::heartbeat:apache): Started vdb1.example.com p_ApacheDisk (ocf::linbit:drbd): Stopped Failed actions: p_ApacheDisk_monitor_0 (node=vdb1.example.com, call=27, rc=6, status=complete, last-rc-change=Wed Nov 27 11:49:36 2013 , queued=23ms, exec=0ms ): not configured p_ApacheDisk_monitor_0 (node=vdb2.example.com, call=15, rc=6, status=complete, last-rc-change=Wed Nov 27 11:49:36 2013 , queued=22ms, exec=1ms ): not configured Got the following in /var/log/messages on DC (node 1): Nov 27 11:49:36 vdb1 cib[538]: notice: cib:diff: Diff: --- 0.43.13 Nov 27 11:49:36 vdb1 cib[538]: notice: cib:diff: Diff: +++ 0.44.1 f4b87d9dee145747f86583cb5eb8276b Nov 27 11:49:36 vdb1 stonith-ng[539]: notice: unpack_config: On loss of CCM Quorum: Ignore Nov 27 11:49:36 vdb1 crmd[543]: notice: do_state_transition: State transition S_IDLE -> S_POLICY_ENGINE [ input=I_PE_CALC cause=C_FSA_INTERNAL origin=abort_transition_graph ] Nov 27 11:49:36 vdb1 pengine[542]: notice: unpack_config: On loss of CCM Quorum: Ignore Nov 27 11:49:36 vdb1 pengine[542]: notice: LogActions: Start p_ApacheDisk#011(vdb2.example.com) Nov 27 11:49:36 vdb1 pengine[542]: notice: process_pe_message: Calculated Transition 92: /var/lib/pacemaker/pengine/pe-input-74.bz2 Nov 27 11:49:36 vdb1 crmd[543]: notice: te_rsc_command: Initiating action 8: monitor p_ApacheDisk_monitor_0 on vdb2.example.com Nov 27 11:49:36 vdb1 crmd[543]: notice: te_rsc_command: Initiating action 6: monitor p_ApacheDisk_monitor_0 on vdb1.example.com (local) Nov 27 11:49:36 vdb1 drbd(p_ApacheDisk)[9807]: ERROR: meta parameter misconfigured, expected clone-max -le 2, but found unset. Nov 27 11:49:36 vdb1 crmd[543]: notice: process_lrm_event: LRM operation p_ApacheDisk_monitor_0 (call=27, rc=6, cib-update=124, confirmed=true) not configured Nov 27 11:49:36 vdb1 crmd[543]: warning: status_from_rc: Action 8 (p_ApacheDisk_monitor_0) on vdb2.example.com failed (target: 7 vs. rc: 6): Error Nov 27 11:49:36 vdb1 crmd[543]: notice: te_rsc_command: Initiating action 7: probe_complete probe_complete on vdb2.example.com - no waiting Nov 27 11:49:36 vdb1 crmd[543]: warning: status_from_rc: Action 6 (p_ApacheDisk_monitor_0) on vdb1.example.com failed (target: 7 vs. rc: 6): Error Nov 27 11:49:36 vdb1 crmd[543]: notice: te_rsc_command: Initiating action 5: probe_complete probe_complete on vdb1.example.com (local) - no waiting Nov 27 11:49:36 vdb1 crmd[543]: notice: run_graph: Transition 92 (Complete=4, Pending=0, Fired=0, Skipped=3, Incomplete=0, Source=/var/lib/pacemaker/pengine/pe-input-74.bz2): Stopped Nov 27 11:49:36 vdb1 pengine[542]: notice: unpack_config: On loss of CCM Quorum: Ignore Nov 27 11:49:36 vdb1 pengine[542]: error: unpack_rsc_op: Preventing p_ApacheDisk from re-starting anywhere in the cluster : operation monitor failed 'not configured' (rc=6) Nov 27 11:49:36 vdb1 pengine[542]: error: unpack_rsc_op: Preventing p_ApacheDisk from re-starting anywhere in the cluster : operation monitor failed 'not configured' (rc=6) Nov 27 11:49:36 vdb1 pengine[542]: notice: process_pe_message: Calculated Transition 93: /var/lib/pacemaker/pengine/pe-input-75.bz2 Nov 27 11:49:36 vdb1 crmd[543]: notice: run_graph: Transition 93 (Complete=0, Pending=0, Fired=0, Skipped=0, Incomplete=0, Source=/var/lib/pacemaker/pengine/pe-input-75.bz2): Complete Nov 27 11:49:36 vdb1 crmd[543]: notice: do_state_transition: State transition S_TRANSITION_ENGINE -> S_IDLE [ input=I_TE_SUCCESS cause=C_FSA_INTERNAL origin=notify_crmd ] I then executed the second command and got this: [root@vdb2 drbd.d]# pcs resource master MasterApacheDisk p_ApacheDisk \ > master-max=1 master-node-max=1 clone-max=2 clone-node-max=1 \ > notify=true [root@vdb2 drbd.d]# pcs status Cluster name: MySQLCluster Last updated: Wed Nov 27 11:52:54 2013 Last change: Wed Nov 27 11:52:39 2013 via cibadmin on vdb1.example.com Stack: corosync Current DC: vdb1.example.com (1) - partition with quorum Version: 1.1.9-3.fc19-781a388 2 Nodes configured, unknown expected votes 4 Resources configured. Online: [ vdb1.example.com vdb2.example.com ] Full list of resources: ClusterIP (ocf::heartbeat:IPaddr2): Started vdb1.example.com Apache (ocf::heartbeat:apache): Started vdb1.example.com Master/Slave Set: MasterApacheDisk [p_ApacheDisk] Stopped: [ vdb1.example.com vdb2.example.com ] Failed actions: p_ApacheDisk_monitor_0 (node=vdb1.example.com, call=27, rc=6, status=complete, last-rc-change=Wed Nov 27 11:49:36 2013 , queued=23ms, exec=0ms ): not configured p_ApacheDisk_monitor_0 (node=vdb2.example.com, call=15, rc=6, status=complete, last-rc-change=Wed Nov 27 11:49:36 2013 , queued=22ms, exec=1ms ): not configured [root@vdb2 drbd.d]# Got the following in log file on /var/log/messages: Nov 27 11:52:39 vdb1 cib[538]: notice: cib:diff: Diff: --- 0.44.3 Nov 27 11:52:39 vdb1 cib[538]: notice: cib:diff: Diff: +++ 0.45.1 d62a8fd52495c636c2bc012ac156d3e2 Nov 27 11:52:39 vdb1 crmd[543]: notice: do_state_transition: State transition S_IDLE -> S_POLICY_ENGINE [ input=I_PE_CALC cause=C_FSA_INTERNAL origin=abort_transition_graph ] Nov 27 11:52:39 vdb1 stonith-ng[539]: notice: unpack_config: On loss of CCM Quorum: Ignore Nov 27 11:52:39 vdb1 pengine[542]: notice: unpack_config: On loss of CCM Quorum: Ignore Nov 27 11:52:39 vdb1 pengine[542]: error: unpack_rsc_op: Preventing MasterApacheDisk from re-starting anywhere in the cluster : operation monitor failed 'not configured' (rc=6) Nov 27 11:52:39 vdb1 pengine[542]: error: unpack_rsc_op: Preventing MasterApacheDisk from re-starting anywhere in the cluster : operation monitor failed 'not configured' (rc=6) Nov 27 11:52:39 vdb1 pengine[542]: notice: process_pe_message: Calculated Transition 94: /var/lib/pacemaker/pengine/pe-input-76.bz2 Nov 27 11:52:39 vdb1 crmd[543]: notice: run_graph: Transition 94 (Complete=0, Pending=0, Fired=0, Skipped=0, Incomplete=0, Source=/var/lib/pacemaker/pengine/pe-input-76.bz2): Complete Nov 27 11:52:39 vdb1 crmd[543]: notice: do_state_transition: State transition S_TRANSITION_ENGINE -> S_IDLE [ input=I_TE_SUCCESS cause=C_FSA_INTERNAL origin=notify_crmd ] I have tried them they way it is specified in the guide and it works. (i.e. by using an intermediate config file). But my question is, why I cannot use the two commands individually? Are there any limitations in doing so? If someone can explain the above errors and the reasons behind them, I would really appreciate. Thank you for your time. Regards, K -- http://www.wbitt.com , http://techsnail.com Computer bugs are like shipwrecks. They are not found, unless they want to be found.
_______________________________________________ Pacemaker mailing list: Pacemaker@oss.clusterlabs.org http://oss.clusterlabs.org/mailman/listinfo/pacemaker Project Home: http://www.clusterlabs.org Getting started: http://www.clusterlabs.org/doc/Cluster_from_Scratch.pdf Bugs: http://bugs.clusterlabs.org