Hello, On 01/10/2012 09:47 AM, neha chatrath wrote: > Hello, > I am using a cluster with following configuration: > > [root@MCG1 neha]# crm configure show > node $id="0686a4d1-c9de-4334-8d33-1a9f6f0755dd" ggns2mexsatsdp22 > node $id="76246d46-f0e4-4ba8-9179-d60aa7c697c8" ggns2mexsatsdp23 > node $id="9d59c9e6-24e0-4684-94ab-c07af7e7a2f0" mcg1 \ > attributes standby="off" > node $id="fb3f06f0-05bf-42ef-a312-c072f589918a" mcg2 \ > attributes standby="off" > primitive ClusterIP ocf:mcg:MCG_VIPaddr_RA \ > params ip="192.168.113.77" cidr_netmask="255.255.255.0" > nic="eth0:1" \ > op monitor interval="40" timeout="20" > primitive RM ocf:mcg:RM_RA \ > op monitor interval="60" role="Master" timeout="30" > on-fail="restart" \ > op monitor interval="40" role="Slave" timeout="40" on-fail="restart" > primitive Tmgr ocf:mcg:TM_RA \ > op monitor interval="60" role="Master" timeout="30" > on-fail="restart" \ > op monitor interval="40" role="Slave" timeout="40" on-fail="restart" > primitive pimd ocf:mcg:PIMD_RA \ > op monitor interval="60" role="Master" timeout="30" > on-fail="standby" \ > op monitor interval="40" role="Slave" timeout="40" on-fail="restart" > ms ms_RM RM \ > meta master-max="1" master-node-max="1" clone-max="2" > clone-node-max="1" notify="true" target-role="Started" > ms ms_Tmgr Tmgr \ > meta master-max="1" master-node-max="1" clone-max="2" > clone-node-max="1" notify="true" target-role="Started" > ms ms_pimd pimd \ > meta master-max="1" master-node-max="1" clone-max="2" > clone-node-max="1" notify="true" target-role="Started" > colocation ip_with_RM inf: ClusterIP ms_RM:Master > colocation ip_with_Tmgr inf: ClusterIP ms_Tmgr:Master > colocation ip_with_pimd inf: ClusterIP ms_pimd:Master > order TM-after-RM inf: ms_RM:promote ms_Tmgr:start > order ip-after-pimd inf: ms_pimd:promote ClusterIP:start > order pimd-after-TM inf: ms_Tmgr:promote ms_pimd:start > property $id="cib-bootstrap-options" \ > dc-version="1.0.11-55a5f5be61c367cbd676c2f0ec4f1c62b38223d7" \ > cluster-infrastructure="Heartbeat" \ > no-quorum-policy="ignore" \ > stonith-enabled="false" > rsc_defaults $id="rsc-options" \ > resource-stickiness="100" \ > migration-threshold="3" > > When I execute "crm node standby" command on the Active node, it leads > to stopping of resourcs on both Active and Standby node. > As per my understanding, this should lead to stopping of resources only > on current Active node and all the resources on the standby node should > get a promote.
try setting interleave=true for the dependent ms resources Regards, Andreas -- Need help with Pacemaker? http://www.hastexo.com/now > > Please comment. > > Thanks and regards > Neha > > > > > _______________________________________________ > Pacemaker mailing list: Pacemaker@oss.clusterlabs.org > http://oss.clusterlabs.org/mailman/listinfo/pacemaker > > Project Home: http://www.clusterlabs.org > Getting started: http://www.clusterlabs.org/doc/Cluster_from_Scratch.pdf > Bugs: http://bugs.clusterlabs.org
signature.asc
Description: OpenPGP digital signature
_______________________________________________ Pacemaker mailing list: Pacemaker@oss.clusterlabs.org http://oss.clusterlabs.org/mailman/listinfo/pacemaker Project Home: http://www.clusterlabs.org Getting started: http://www.clusterlabs.org/doc/Cluster_from_Scratch.pdf Bugs: http://bugs.clusterlabs.org