On Tue, Aug 16, 2011 at 7:21 PM, Vladislav Bogdanov <bub...@hoster-ok.com> wrote: > Hi, > > I recently discovered that when I stop pacemaker on DC node (for > upgrade), that node is shortly fenced by a new DC. > > Fencing is caused by not-stopped (from the PoV of new DC) clone instance > (dlm in my case) which was actually stopped:
[snip] > This is 100% reproducible in my setup, so I can take hb_report if this > is needed. yes please _______________________________________________ Pacemaker mailing list: Pacemaker@oss.clusterlabs.org http://oss.clusterlabs.org/mailman/listinfo/pacemaker Project Home: http://www.clusterlabs.org Getting started: http://www.clusterlabs.org/doc/Cluster_from_Scratch.pdf Bugs: http://developerbugs.linux-foundation.org/enter_bug.cgi?product=Pacemaker