Il 04/04/2011 20:03, Andrew Daugherity ha scritto: [cut] > The APC PDUs do support outlet groups spanning several PDUs, using multicast I > believe. There's even a note about it in README.rackpdu in the cluster-glue > package: > ==== > In case your nodes are equipped with multiple power supplies, the > PDU supports synchronous operation on multiple outlets on up to > four Switched Rack PDUs. See the User's Guide for more > information on how to setup outlet groups. > ==== > > What I'm not clear about is how to tell the apcmaster stonith plugin which > outlet group to control. The only parameters mentioned in its built-in help > are > ipaddr, login, and password.
thank you very much ...I've not seen such feature before ...I'll make some tests. Christian _______________________________________________ Pacemaker mailing list: [email protected] http://oss.clusterlabs.org/mailman/listinfo/pacemaker Project Home: http://www.clusterlabs.org Getting started: http://www.clusterlabs.org/doc/Cluster_from_Scratch.pdf Bugs: http://developerbugs.linux-foundation.org/enter_bug.cgi?product=Pacemaker