Hello,
I'm sorry, but I didn't found any mail list for SBD only, therefore I try to 
post it here:
we’ve got unfortunately big problems with SBD. We use two nodes cluster 
(HP-Blades) mit SBD-device as quorum on the third server (open-iscsi-server, 
VMWare-Server). These two nodes connect to the open-iscsi-server via 
open-iscsi. We have to set the watchdog timeout to 420 sec. In case we switch 
the open-iscsi-server off, we found out that after 120-130 sec. both nodes 
reset (why not after 420 sec?). We checked SBD without corosync and pacemaker – 
the same behavior. We checked open-iscsi without running SBD –both nodesrun 
without reset. As you can see the problem is only SBD.
Are there any limits in SBD? In the SBD-Wiki there is no word about that.
Just for info:
bash#:/root>sbd -d /dev/sda dump
Header version : 2
Number of slots : 255
Sector size : 512
Timeout (watchdog) : 420
Timeout (allocate) : 2
Timeout (loop) : 1
Timeout (msgwait) : 10

bash#:/root>crm configure show | grep -A 1 sbd
primitive st_sbd stonith:external/sbd \
 params sbd_device="/dev/sda" \
 op monitor interval="15s" timeout="840s"
--
clone sbd_clone st_sbd \
 meta target-role="Started"

Thank you in advance
Best regards 
Vlad




---
Exklusiv: Neue E-Mail-Adresse @iPhone.de jetzt verfügbar!
Sichern Sie sich jetzt ihre persönliche 
http://www.iphone.de/iphonemail/index.html?pid=10111947021

_______________________________________________
Pacemaker mailing list: Pacemaker@oss.clusterlabs.org
http://oss.clusterlabs.org/mailman/listinfo/pacemaker

Project Home: http://www.clusterlabs.org
Getting started: http://www.clusterlabs.org/doc/Cluster_from_Scratch.pdf
Bugs: http://developerbugs.linux-foundation.org/enter_bug.cgi?product=Pacemaker

Reply via email to