Hi guys, We followed the debug steps and using perf we got the following performance trace:
- 84.56% 0.01% ovn-controller [.] main - 84.56% main - 78.52% pinctrl_run - 39.14% lport_lookup_by_name - 36.66% ovsdb_idl_index_find - skiplist_find - 36.36% skiplist_forward_to (inlined) - skiplist_forward_to_ - 31.99% ovsdb_idl_index_generic_comparer.part.0 - 24.68% ovsdb_datum_compare_3way - 13.18% ovsdb_atom_compare_3way 8.38% json_string 6.27% __strcmp_evex 6.28% ovsdb_idl_read + 1.07% sbrec_port_binding_index_set_logical_port 0.72% ovsdb_idl_index_destroy_row 0.60% ovsdb_idl_index_init_row - 15.04% extract_ip_addresses - parse_and_store_addresses - 9.90% add_ipv6_netaddr - 9.36% __GI_inet_ntop (inlined) + inet_ntop6 (inlined) + 2.78% ipv6_parse_cidr_len + 2.14% ip_parse_cidr_len + 8.35% smap_get + 4.93% smap_get_int + 3.00% shash_find_data + 2.00% ipv6_parse + 1.31% eth_addr_from_string - 4.46% bfd_run - 2.00% sset_add 1.43% hash_bytes 0.81% encaps_run Just to recall, only when the ovn-controller receives the update for ovn-interconnect logical flows (that's not happen with regular logical flows) that load spike happens. We are looking into the lport_lookup_by_name function to try to understand what is the relation with the ovn-interconnect logical flows. Regards, Tiago Pires On Tue, Jan 7, 2025 at 5:54 AM Felix Huettner <felix.huettner@stackit.cloud> wrote: > > On Sat, Jan 04, 2025 at 09:59:28PM -0500, Satish Patel wrote: > > Hi Felix, > > > > Are there any documents on OVN troubleshooting the way you explain? LIke > > what logs to look at, what tools to use to dump perf data and tech support > > style data to drill down the issue before we report to developers. I > > heard in the past related ovn-controller CPU usage 100% etc. But there is > > no better way to find out what causes those spikes and errors. > > Hi Satish, > > i do not know of any documents regarding that. The questions below are > based on my experience of looking at similar issues in the past. > > I also do not yet have a nice way to get perf information for spikes, > but most of the time running inc-engine/recompute converts a spike to a > continuous 100% cpu usage, which i find easier to analyse. > > To get the perf information you can do the following: > * Ensure you have ovn-controller debug symbols available (that depends > on your installation method how to do that) > * Install "perf". E.g. for ubuntu it would be something like "apt install > linux-tools-generic binutils libc-dbg" > * Run "perf record -p $(pidof ovn-controller) -g --call-graph dwarf" > while the recomputes are running > * Press CTRL+C after a few recompute iterations > * Wait for "perf record" to finish. Do not press CTRL+C again until it > is done. Depending on how long it ran this can take some time. > * Run "perf report -g". This will parse the profile and output a nice ui > * You will see a list of functions and before them the percentage of CPU > time that the process spend in there (once in the function only and > once in the function and all subfunctions) > * Expand the tree using the "+" key and follow mostly the top 2 > percentages after expansion > * Probably somewhere in there there is something to optimize (or that > has already been optimized) > > You will see something similar as the "performance trace" in this commit > message > https://github.com/ovn-org/ovn/commit/ea619bf64ce1ae00996928f7ed15309a690ee3b9 > In that case the bfd_calculate_chassis was the one that was optimized. > > I hope that helps. > > Felix > > > > > > On Thu, Jan 2, 2025 at 9:48 AM Felix Huettner via discuss < > > ovs-discuss@openvswitch.org> wrote: > > > > > On Thu, Jan 02, 2025 at 08:47:34AM -0300, Tiago Pires via discuss wrote: > > > > Hi all, > > > > > > > > While creating ovn interconnect logical flows (Transit switch, LRPs > > > > and LSPs) for a Logical Router in an AZ, there is load spike in all > > > > chassis's ovn-controllers to 100%. > > > > This remains for 1 minute and half and returns to normal after the > > > > logical flows are installed. > > > > Since this behavior only manifests itself while creating ovn > > > > interconnect logical flows, enabling the debug logs shows that the > > > > ovn-controller receives from SB the following change: > > > > > > > > > > > 2024-12-26T17:38:15.023Z|10562646|inc_proc_eng|DBG|lib/inc-proc-eng.c:379: > > > > node: SB_encap, old_state Unchanged, new_state Stale > > > > > > > 2024-12-26T17:38:15.023Z|10562647|inc_proc_eng|DBG|lib/inc-proc-eng.c:379: > > > > node: mff_ovn_geneve, old_state Unchanged, new_state Stale > > > > > > > 2024-12-26T17:38:15.023Z|10562648|inc_proc_eng|DBG|lib/inc-proc-eng.c:379: > > > > node: physical_flow_output, old_state Unchanged, new_state Stale > > > > > > > 2024-12-26T17:38:15.023Z|10562649|inc_proc_eng|DBG|lib/inc-proc-eng.c:379: > > > > node: flow_output, old_state Unchanged, new_state Stale > > > > 2024-12-26T17:38:15.032Z|10562650|jsonrpc|DBG|ssl:1XX.XX.XX.X16:6642: > > > > received notification, method="update3", > > > > > > > params=[["monid","OVN_Southbound"],"9c54ec46-83a4-4deb-877d-3089a99ae482",{"SB_Global > > > > > > > ":{"019c4225-e637-4881-b382-36fdfcb9e0c9":{"modify":{"nb_cfg":34448}}},"Port_Binding":{"4230d38a-75cd-4f1c-9fde-62e753958656":{"insert":{"up":false,"tunnel_key":7,"mac":"16:00:01:f4:03:cb > > > > 169.254 .30.3/24 > > > > > > > fe80:30::3/64","datapath":["uuid","e84addb8-efdd-48bc-8454-8dd76a4a5a19"],"logical_port":"bd7bae47-2482-41cc-9486-e66f9d7b25bf-lrp-793b8","type":"patch"}},"f4d71615-88b8-4274-87ab-448cf8 > > > > c6a6ee":{"insert":{"up":false,"tunnel_key":6,"mac":"16:00:01:75:f8:87 > > > > 169.254.10.1/24 > > > > > > > fe80:10::1/64","datapath":["uuid","e84addb8-efdd-48bc-8454-8dd76a4a5a19"],"logical_port":"bd7bae47-2482-41cc- > > > > > > > 9486-e66f9d7b25bf-lrp-ba453","type":"patch"}},"3eac57dd-386c-43b0-bf5b-8225941b52cb":{"insert":{"up":false,"tunnel_key":5,"mac":"16:00:01:9a:30:fa > > > > 169.254.40.4/24 fe80:40::4/64","datapath":["uuid > > > > > > > ","e84addb8-efdd-48bc-8454-8dd76a4a5a19"],"logical_port":"bd7bae47-2482-41cc-9486-e66f9d7b25bf-lrp-36ac0","type":"patch"}},"7295d5c6-ff8d-4f4f-b1a5-eb1ca87fcb7d":{"insert":{"up":false,"tunnel_key > > > > ":8,"mac":"16:00:01:de:df:b5 169.254.20.2/24 > > > > > > > fe80:20::2/64","datapath":["uuid","e84addb8-efdd-48bc-8454-8dd76a4a5a19"],"logical_port":"bd7bae47-2482-41cc-9486-e66f9d7b25bf-lrp-c21c6","type":"patc > > > > > > > h"}}},"Logical_Flow":{"224852f2-9a46-4569-b51d-5d340ed6f4b4":{"modify":{"logical_dp_group":["uuid","bd825723-9a0e-451c-b5ad-b7d6f9cc75e4"]}},"05f5d515-bccf-47c1-9d55-8a4dfce88822":{"insert":{"pip > > > > eline":"ingress","match":"inport == > > > > \"bd7bae47-2482-41cc-9486-e66f9d7b25bf-lrp-36ac0\" && ip6.dst == > > > > > > > fe80::/64","priority":194,"logical_datapath":["uuid","e84addb8-efdd-48bc-8454-8dd76a4a5a19"]," > > > > table_id":13,"actions":"ip.ttl--; reg8[0..15] = 0; xxreg0 = ip6.dst; > > > > xxreg1 = fe80::1400:1ff:fe9a:30fa; eth.src = 16:00:01:9a:30:fa; > > > > outport = \"bd7bae47-2482-41cc-9486-e66f9d7b25bf-lrp-36ac0\"; > > > > flags.loopback = 1; > > > > > > > next;"}},"c67ec1ee-bfc1-47e0-b35c-95fcc2adc13b":{"modify":{"logical_dp_group": > > > > > > > > The addresses from the above change (16:00:01:75:f8:87 169.254.10.1/24 > > > > fe80:10::1/64) are configured into the LRP connected to the transit > > > > switch. > > > > > > > > After while another incremental processing is started: > > > > > > > > 2024-12-26T17:38:18.035Z|11190795|coverage|INFO|Skipping details of > > > > duplicate event coverage for hash=db09e857 > > > > 2024-12-26T17:38:18.035Z|11190796|poll_loop|DBG|wakeup due to [POLLIN] > > > > on fd 3 (1XX.XX.XX.X99:47382<->1XX.XX.XX.X16:6642) at > > > > lib/stream-ssl.c:842 (100% CPU usage) > > > > 2024-12-26T17:38:18.035Z|11190797|inc_proc_eng|DBG|Initializing new > > > > run > > > 2024-12-26T17:38:18.035Z|11190798|inc_proc_eng|DBG|lib/inc-proc-eng.c:379: > > > > node: SB_sb_global, old_state Updated, new_state Stale > > > > > > > 2024-12-26T17:38:18.035Z|11190799|inc_proc_eng|DBG|lib/inc-proc-eng.c:379: > > > > node: northd_options, old_state Unchanged, new_state Stale > > > > > > > 2024-12-26T17:38:18.035Z|11190800|inc_proc_eng|DBG|lib/inc-proc-eng.c:379: > > > > node: SB_dhcp_options, old_state Unchanged, new_state Stale > > > > > > > 2024-12-26T17:38:18.035Z|11190801|inc_proc_eng|DBG|lib/inc-proc-eng.c:379: > > > > node: SB_dhcpv6_options, old_state Unchanged, new_state Stale > > > > > > > 2024-12-26T17:38:18.035Z|11190802|inc_proc_eng|DBG|lib/inc-proc-eng.c:379: > > > > node: dhcp_options, old_state Unchanged, new_state Stale > > > > > > > 2024-12-26T17:38:18.035Z|11190803|inc_proc_eng|DBG|lib/inc-proc-eng.c:379: > > > > node: SB_address_set, old_state Unchanged, new_state Stale > > > > > > > > In other chassis we observerd the recompute time increasing to 18secs: > > > > > > > > 2024-12-26T17:38:46.463Z|40096697|poll_loop|INFO|Dropped 72 log > > > > messages in last 6 seconds (most recently, 0 seconds ago) due to > > > > excessive rate 2024-12-26T17:38:46.463Z|40096698|poll_loop|INFO|wakeup > > > > due to [POLLIN] on fd 26 (1XX.XX.XX.6:56350<->1XX.XX.XX.X16:6642) at > > > > lib/stream-ssl.c:842 (99% CPU usage) > > > > 2024-12-26T17:38:52.442Z|40096699|poll_loop|INFO|Dropped 72 log > > > > messages in last 6 seconds (most recently, 0 seconds ago) due to > > > > excessive rate 2024-12-26T17:38:52.442Z|40096700|poll_loop|INFO|wakeup > > > > due to [POLLIN] on fd 26 (1XX.XX.XX.6:56350<->1XX.XX.XX.X16:6642) at > > > > lib/stream-ssl.c:842 (102% CPU usage) > > > > 2024-12-26T17:38:58.409Z|40096701|poll_loop|INFO|Dropped 72 log > > > > messages in last 6 seconds (most recently, 0 seconds ago) due to > > > > excessive rate 2024-12-26T17:38:58.409Z|40096702|poll_loop|INFO|wakeup > > > > due to [POLLIN] on fd 26 (1XX.XX.XX.6:56350<->1XX.XX.XX.X16:6642) at > > > > lib/stream-ssl.c:842 (101% CPU usage) > > > > 2024-12-26T17:39:04.477Z|40096703|poll_loop|INFO|Dropped 72 log > > > > messages in last 6 seconds (most recently, 0 seconds ago) due to > > > > excessive rate 2024-12-26T17:39:04.477Z|40096704|poll_loop|INFO|wakeup > > > > due to [POLLIN] on fd 26 (1XX.XX.XX.6:56350<->1XX.XX.XX.X16:6642) at > > > > lib/stream-ssl.c:842 (98% CPU usage) > > > > 2024-12-26T17:39:27.896Z|40096705|inc_proc_eng|INFO|node: > > > > logical_flow_output, recompute (forced) took 18932ms > > > > 2024-12-26T17:39:28.612Z|40096706|inc_proc_eng|INFO|node: > > > > physical_flow_output, recompute (forced) took 670ms > > > > 2024-12-26T17:39:30.614Z|40096707|timeval|WARN|Unreasonably long > > > > 22134ms poll interval (19780ms user, 2315ms system) > > > > 2024-12-26T17:39:30.614Z|40096708|timeval|WARN|faults: 2634558 minor, > > > > 0 major 2024-12-26T17:39:30.614Z|40096709|timeval|WARN|disk: 0 reads, > > > > 8 writes 2024-12-26T17:39:30.614Z|40096710|timeval|WARN|context > > > > switches: 0 voluntary, 2688 involuntary > > > > > > > > This behavior only happens with ovn interconnect logical flows, do you > > > > know any known issue regarding it? > > > > > > Hi Tiago, > > > > > > from the log above it seems like some part of the previous incremental > > > processing run failed and caused a recompute afterwards. So the last > > > logs are no longer incrementally processed. > > > > > > There should be some log line in between similar to "...forcing recompute > > > next time...". That might help you find the cause of the recompute. > > > > > > Additionally you should be able to trigger a recompute manually with > > > "ovn-appctl inc-engine/recompute". Then you will probably observe > > > similar logs. > > > You could then attach a perf to the ovn-controller for one or more > > > recomputes and use "perf record" and "perf report" with call graphs to > > > figure out what exactly takes long. That might be helpful information > > > for further optimizations. > > > > > > Also ovn got significant improvements in incremental processing since > > > 23.03, so an upgrade might help as well. > > > > > > Hope that helps > > > Felix > > > > > > > > > > > > > > #Versions in use > > > > > > > > $ ovn-nbctl -V > > > > ovn-nbctl 23.03.1 > > > > Open vSwitch Library 3.1.3 > > > > DB Schema 7.0.0 > > > > > > > > $ ovs-vsctl -V > > > > ovs-vsctl (Open vSwitch) 3.1.3 > > > > DB Schema 8.3.1 > > > > > > > > external_ids: ovn-monitor-all="true", > > > > ovn-ofctrl-wait-before-clear="10000", ovn-openflow-probe-interval="0", > > > > ovn-remote-probe-interval="180000" > > > > > > > > Regards, > > > > > > > > Tiago Pires > > > > > > > > -- > > > > > > > > > > > > > > > > > > > > _‘Esta mensagem é direcionada apenas para os endereços constantes no > > > > cabeçalho inicial. Se você não está listado nos endereços constantes no > > > > cabeçalho, pedimos-lhe que desconsidere completamente o conteúdo dessa > > > > mensagem e cuja cópia, encaminhamento e/ou execução das ações citadas > > > estão > > > > imediatamente anuladas e proibidas’._ > > > > > > > > > > > > * **‘Apesar do Magazine Luiza tomar > > > > todas as precauções razoáveis para assegurar que nenhum vírus esteja > > > > presente nesse e-mail, a empresa não poderá aceitar a responsabilidade > > > por > > > > quaisquer perdas ou danos causados por esse e-mail ou por seus anexos’.* > > > > > > > > > > > > > > > > _______________________________________________ > > > > discuss mailing list > > > > disc...@openvswitch.org > > > > https://mail.openvswitch.org/mailman/listinfo/ovs-discuss > > > _______________________________________________ > > > discuss mailing list > > > disc...@openvswitch.org > > > https://mail.openvswitch.org/mailman/listinfo/ovs-discuss > > > -- _‘Esta mensagem é direcionada apenas para os endereços constantes no cabeçalho inicial. Se você não está listado nos endereços constantes no cabeçalho, pedimos-lhe que desconsidere completamente o conteúdo dessa mensagem e cuja cópia, encaminhamento e/ou execução das ações citadas estão imediatamente anuladas e proibidas’._ * **‘Apesar do Magazine Luiza tomar todas as precauções razoáveis para assegurar que nenhum vírus esteja presente nesse e-mail, a empresa não poderá aceitar a responsabilidade por quaisquer perdas ou danos causados por esse e-mail ou por seus anexos’.* _______________________________________________ discuss mailing list disc...@openvswitch.org https://mail.openvswitch.org/mailman/listinfo/ovs-discuss