Maryam:


Please see my response below.





Regards,



Alok Gupta

732-420-7007

MT B2 3D30

ag1...@att.com



-----Original Message-----
From: SULLIVAN, BRYAN L
Sent: Tuesday, November 08, 2016 7:44 AM
To: GUPTA, ALOK <ag1...@att.com>
Subject: FW: [opnfv-tech-discuss] [doctor][VES][barometer] OVS link status 
notifications for OpenStack from collectd - Open Questions



Can you respond on the list? I'm unsure what the answer should be.



Thanks,

Bryan Sullivan | AT&T



-----Original Message-----

From: 
opnfv-tech-discuss-boun...@lists.opnfv.org<mailto:opnfv-tech-discuss-boun...@lists.opnfv.org>
 [mailto:opnfv-tech-discuss-boun...@lists.opnfv.org] On Behalf Of Tahhan, Maryam

Sent: Tuesday, November 08, 2016 6:52 AM

To: 
opnfv-tech-discuss@lists.opnfv.org<mailto:opnfv-tech-discuss@lists.opnfv.org>

Subject: [opnfv-tech-discuss] [doctor][VES][barometer] OVS link status 
notifications for OpenStack from collectd - Open Questions



Hi Folks

 For the OVS events collectd plugin we wrote as part of barometer, we are 
currently sending a notification message from collectd with a level that is set 
to WARNING for when the link status is detected to be down.

AG Response: When an existing link is detected to be down, we should generate a 
Major Severity Fault event

So this means that when the status changes from "Unknown" to "down" when a new 
interface is added a warning message will be generated.

AG response: for New Interfaces we do not expect any new events. That will 
cause lot of noise...since they are not actionable events.





So from a Doctor/VES perspective:

1. When do you expect to see a warning message vs an informational message? 
When the link status only changes from Up to down : AG Response: correct, send 
a Fault event with Major Severity.



2. Do you want to know when the status changes from unknown to down? AG 
Response: correct, send a Fault event with Major Severity.



3. Should we allow the notification severity to be configurable for link 
status? Or should we from a collectd point of view provide you with 
informational messages only and let you decide a severity? AG response: Please 
provide fault event with Major Severity

 BR

Maryam

_______________________________________________

opnfv-tech-discuss mailing list

opnfv-tech-discuss@lists.opnfv.org<mailto:opnfv-tech-discuss@lists.opnfv.org>

https://lists.opnfv.org/mailman/listinfo/opnfv-tech-discuss
_______________________________________________
opnfv-tech-discuss mailing list
opnfv-tech-discuss@lists.opnfv.org
https://lists.opnfv.org/mailman/listinfo/opnfv-tech-discuss

Reply via email to