Am 17.12.2014 um 08:47 schrieb Weedy: > > On Nov 28, 2014 3:24 PM, "Weedy" <weedy2...@gmail.com > <mailto:weedy2...@gmail.com>> wrote: >> >> >> On Nov 28, 2014 5:23 AM, "Heiner Kallweit" <hkallwe...@gmail.com >> <mailto:hkallwe...@gmail.com>> wrote: >> > Anybody with a 8216-based device who can test this? >> >> Me me me, me me. >> 4300 currently running trunk with 43332 reverted. >> I am at your service. > > Is the current trunk fixed? You never replied after this. > > Do I need to keep 43332 reverted to keep autoneg working? > Ticket 18415 was closed as it was confirmed that as at least version >=43419 is ok. (I assume 43410 fixed the issue.) Therefore current trunk should be ok.
However if you want to check further what the actual root cause was: -> Re-enable the additional reset by reverting 43410 -> Issue there? -> If yes, check whether inserting a mdiobus_write(bus, i, MII_BMCR, BMCR_ANENABLE); before mdiobus_write(bus, i, MII_BMCR, BMCR_RESET | BMCR_ANENABLE); in ar8xxx_phy_init fixes it. Heiner _______________________________________________ openwrt-devel mailing list openwrt-devel@lists.openwrt.org https://lists.openwrt.org/cgi-bin/mailman/listinfo/openwrt-devel