On Mon, Nov 24, 2014 at 3:45 AM, Heiner Kallweit <hkallwe...@gmail.com> wrote: > > On Mon, Nov 24, 2014 at 1:06 AM, Felix Fietkau <n...@openwrt.org> wrote: >> >> On 2014-11-23 23:03, Weedy wrote: >> > >> > On Nov 23, 2014 4:35 PM, "Weedy" <weedy2...@gmail.com >> > <mailto:weedy2...@gmail.com>> wrote: >> >> >> >> >> >> On Nov 19, 2014 8:47 AM, "John Crispin" <blo...@openwrt.org >> > <mailto:blo...@openwrt.org>> wrote: >> >> > >> >> > >> >> > >> >> > On 19/11/2014 14:44, Weedy wrote: >> >> > > >> >> > > On Oct 30, 2014 5:08 PM, "Heiner Kallweit" <hkallwe...@gmail.com >> > <mailto:hkallwe...@gmail.com> >> >> > > <mailto:hkallwe...@gmail.com <mailto:hkallwe...@gmail.com>>> wrote: >> >> > >> >> >> > >> Am 30.10.2014 um 07:22 schrieb Heiner Kallweit: >> >> > >> > Am 30.10.2014 um 03:36 schrieb Florian Fainelli: >> >> > >> >> Le 28/10/2014 11:46, Heiner Kallweit a écrit : >> >> > >> >>> After a little more thinking about it and looking at the code >> >> > >> >>> I >> >> > > basically have two questions: >> >> > >> >>> >> >> > >> >>> 1. >> >> > >> >>> Is it actually needed to exclude certain phy's in >> >> > > ar8xxx_phy_config_aneg? >> >> > >> >>> (At least for AR8327 it doesn't get called with an addr != 0 >> > anyway) >> >> > >> >>> Else we could remove ar8xxx_phy_config_aneg and directly >> >> > >> >>> register >> >> > > genphy_config_aneg as >> >> > >> >>> callback for autoneg configuration. >> >> > >> >> >> >> > >> >> Address 0 is special, since this is a MDIO broadcast address >> >> > >> >> that >> >> > > will usually be handled by switches as "write to all front-panel >> > ports". >> >> > >> >> >> >> > >> >>> >> >> > >> >>> 2. >> >> > >> >>> Call sequence with regard to ar8216 is: >> >> > >> >>> ar8216: ar8xxx_phy_probe >> >> > >> >>> phy: phy_attach_direct >> >> > >> >>> phy: phy_init_hw >> >> > >> >>> ar8216: ar8xxx_phy_config_init >> >> > >> >>> ar8216: ar8xxx_phy_config_aneg >> >> > >> >>> >> >> > >> >>> ar8216 driver handles AR8327/AR8337 different from the other >> >> > > supported switch types. >> >> > >> >>> ar8xxx_start incl. more detailed configuration is called from >> >> > > ar8xxx_phy_probe already. >> >> > >> >>> For the other switch types it's called from >> > ar8xxx_phy_config_init. >> >> > >> >>> >> >> > >> >>> I wonder whether doing detailed configuration in the probe >> >> > >> >>> stage >> >> > > might be too early. >> >> > >> >>> phy_init_hw resets the switch anyway later. >> >> > >> >>> Doing the detailed setup in ar8xxx_phy_config_init seems to be >> >> > > more suited however >> >> > >> >>> there might be good reason why it's handled the way it is. >> >> > >> >> >> >> > >> >> I suppose that you could re-advertise auto-negotiation by >> >> > >> >> calling >> >> > > genphy_config_advert() in the config_init routine. >> >> > >> > >> >> > >> > The actual problem is caused by BMCR_ANENABLE being cleared by >> >> > >> > the >> >> > > reset in phy_init_hw. >> >> > >> > As far as I can see genphy_config_advert doesn't bring back >> > this flag. >> >> > >> > What does genphy_config_aneg mainly do? >> >> > >> > - call genphy_config_advert >> >> > >> > - check if BMCR_ANENABLE is set >> >> > >> > - if it's not, call genphy_restart_aneg >> >> > >> > Therefore, to bring back BMCR_ANENABLE, we have to call >> >> > > genphy_config_aneg or genphy_restart_aneg. >> >> > >> > genphy_restart_aneg most likely is sufficient, however I don't >> >> > >> > see >> >> > > that genphy_config_aneg >> >> > >> > can do any harm if being called with addr == 0. >> >> > >> > At least for me it works perfectly fine to call >> >> > >> > genphy_config_aneg >> >> > > for all addr's. >> >> > >> > >> >> > >> > Rgds, Heiner >> >> > >> > >> >> > >> >> >> >> > >> >>> >> >> > >> >>> Rgds, >> >> > >> >>> Heiner >> >> > >> >>> >> >> > >> >>> >> >> > >> >>> Am 27.10.2014 um 22:00 schrieb Heiner Kallweit: >> >> > >> >>>> With two different TPLINK routers (both with a AR8327N >> >> > >> >>>> switch) I >> >> > > faced the issue that with >> >> > >> >>>> kernel 3.14 certain switch ports used 10MBit/half only. >> >> > >> >>>> Under kernel 3.10 everything was fine and the same ports used >> >> > > 1000MBit/full. >> >> > >> >>>> >> >> > >> >>>> As the ar8216 driver is the same I had a look at the common >> >> > >> >>>> phy >> >> > > code in drivers/net/phy. >> >> > >> >>>> In function phy_init_hw in phy_device.c kernel 3.14 resets >> >> > >> >>>> the >> >> > > phy whilst 3.10 does not. >> >> > >> >>>> >> >> > >> >>>> The issue turned out to be that when resetting only flag >> >> > > BMCR_RESET is set, not BMCR_ANENABLE. >> >> > >> >>>> (In ar8216.c always both flags are set when the switch is >> >> > >> >>>> reset) >> >> > >> >>>> Therefore autoneg was not enabled. Also later in the boot >> > process >> >> > > it doesn't get enabled. >> >> > >> >>>> Adding BMCR_ANENABLE solved the problem and now also under >> >> > >> >>>> 3.14 >> >> > > all ports use 1000MBit/full. >> >> > >> >>>> >> >> > >> >>>> However I'm not sure whether it's a poper fix to add >> >> > > BMCR_ANENABLE in this generic phy function. >> >> > >> >>>> It might not be appropriate for other phy's. >> >> > >> >>>> >> >> > >> >>>> After resetting the switch later in the boot process >> >> > > ar8xxx_phy_config_aneg is called with >> >> > >> >>>> phydev->addr being 0. >> >> > >> >>>> In this case the function returns immediately. Otherwise it >> > would >> >> > > call genphy_config_aneg. >> >> > >> >>>> Calling genphy_config_aneg would also solve the problem as it >> >> > > checks for BMCR_ANENABLE >> >> > >> >>>> being set and sets it if needed. >> >> > >> >>>> I don't know the reason why genphy_config_aneg isn't called >> >> > >> >>>> in >> >> > > case of addr 0. >> >> > >> >>>> Or is this a typo and the check actually should be addr != 0 >> >> > >> >>>> ? >> >> > >> >>>> >> >> > >> >>>> Rgds, Heiner >> >> > >> >>>> >> >> > >> >> >> > >> The following rudimentary patch works fine for me with kernel >> > 3.14.18 on >> >> > >> TP-LINK TL-WDR4900 (mpc85xx with AR8327Nv4) >> >> > >> TP-LINK TL-WDR4300 ( ar71xx with AR8327Nv2) >> >> > >> >> >> > >> Apart from using genphy_config_aneg also for addr==0 I replaced >> >> > > msleep(1000) >> >> > >> with a polling function inspired by phy_poll_reset in phy_device.c >> >> > >> On AR8327 the reset actually takes less than 20ms. Sleeping for >> > 1000ms >> >> > >> seems to be a waste of time. >> >> > >> >> >> > >> Little more work would be needed to make it a proper patch: >> >> > >> - move ar8xxx_phy_poll_reset more to the beginning so that it is >> > defined >> >> > >> before being used in any xxxx_hw_init function >> >> > >> - replace msleep(1000) also in the other xxxx_hw_init functions >> >> > >> - remove pr_info debug message or make it at least pr_dbg >> >> > >> - insert some comments >> >> > >> - use git format-patch output >> >> > >> >> >> > >> Rgds, Heiner >> >> > >> >> >> > >> >> >> > >> --- ar8216.c.orig 2014-10-30 21:50:19.999723156 +0100 >> >> > >> +++ ar8216.c 2014-10-30 21:42:11.996481099 +0100 >> >> > >> @@ -1591,6 +1591,29 @@ >> >> > >> #endif >> >> > >> >> >> > >> static int >> >> > >> +ar8xxx_phy_poll_reset(struct mii_bus *bus, int num_phys) >> >> > >> +{ >> >> > >> + unsigned int sleep_msecs = 20; >> >> > >> + int ret, elapsed, i; >> >> > >> + >> >> > >> + for(elapsed = sleep_msecs; elapsed <= 600; elapsed += >> >> > > sleep_msecs) { >> >> > >> + msleep(sleep_msecs); >> >> > >> + for (i = 0; i < num_phys; i++) { >> >> > >> + ret = mdiobus_read(bus, i, MII_BMCR); >> >> > >> + if (ret < 0) return ret; >> >> > >> + if (ret & BMCR_RESET) break; >> >> > >> + if (i == num_phys - 1) { >> >> > >> + usleep_range(1000, 2000); >> >> > >> + pr_info("ar8xxx_phy_poll_reset >> >> > > finished in %u ms\n", >> >> > >> + elapsed); >> >> > >> + return 0; >> >> > >> + } >> >> > >> + } >> >> > >> + } >> >> > >> + return -ETIMEDOUT; >> >> > >> +} >> >> > >> + >> >> > >> +static int >> >> > >> ar8327_hw_init(struct ar8xxx_priv *priv) >> >> > >> { >> >> > >> struct mii_bus *bus; >> >> > >> @@ -1620,7 +1643,7 @@ >> >> > >> mdiobus_write(bus, i, MII_BMCR, BMCR_RESET | >> >> > > BMCR_ANENABLE); >> >> > >> } >> >> > >> >> >> > >> - msleep(1000); >> >> > >> + ar8xxx_phy_poll_reset(bus, AR8327_NUM_PHYS); >> >> > >> >> >> > >> return 0; >> >> > >> } >> >> > >> @@ -2840,15 +2863,6 @@ >> >> > >> return ret; >> >> > >> } >> >> > >> >> >> > >> -static int >> >> > >> -ar8xxx_phy_config_aneg(struct phy_device *phydev) >> >> > >> -{ >> >> > >> - if (phydev->addr == 0) >> >> > >> - return 0; >> >> > >> - >> >> > >> - return genphy_config_aneg(phydev); >> >> > >> -} >> >> > >> - >> >> > >> static const u32 ar8xxx_phy_ids[] = { >> >> > >> 0x004dd033, >> >> > >> 0x004dd034, /* AR8327 */ >> >> > >> @@ -3020,7 +3034,7 @@ >> >> > >> .remove = ar8xxx_phy_remove, >> >> > >> .detach = ar8xxx_phy_detach, >> >> > >> .config_init = ar8xxx_phy_config_init, >> >> > >> - .config_aneg = ar8xxx_phy_config_aneg, >> >> > >> + .config_aneg = genphy_config_aneg, >> >> > >> .read_status = ar8xxx_phy_read_status, >> >> > >> .driver = { .owner = THIS_MODULE }, >> >> > >> }; >> >> > >> _______________________________________________ >> >> > >> openwrt-devel mailing list >> >> > >> openwrt-devel@lists.openwrt.org >> > <mailto:openwrt-devel@lists.openwrt.org> >> > <mailto:openwrt-devel@lists.openwrt.org >> > <mailto:openwrt-devel@lists.openwrt.org>> >> >> > >> https://lists.openwrt.org/cgi-bin/mailman/listinfo/openwrt-devel >> >> > > >> >> > > I feel like this shouldn't die off in the depths of the ML >> >> > > >> >> > >> >> > we had a call about it today, this patch and the other ar821x patches >> >> > will be handled soon >> >> >> >> You guys bumped trunk to 3.14 but didn't fix this. >> > >> > It's also broken in 43342. >> > >> > For me this manifests as the WAN port is stuck at 1000T so my 100T DSL >> > modem doesn't exist. Lucky I keep spare switches around. >> On what device is it broken for you? I did apply Heiner Kallweit's >> fixes, and it worked for me. >> >> - Felix
TL-WDR4300 That was the topic of the first patches > > The problem with the non-working WAN port was reported to me also by others. > Using genphy_config_aneg with phy 0 seems to cause this. > The following fix which I sent Nov 21st is still waiting to be applied. You didn't attach or paste anything. > ar8216: Fix issue with autoneg being disabled under 3.14, revert 43332 Thanks for this. _______________________________________________ openwrt-devel mailing list openwrt-devel@lists.openwrt.org https://lists.openwrt.org/cgi-bin/mailman/listinfo/openwrt-devel