Hi Takashi,

What OpenStack release are you running?  iSCSI multipath support was added very 
late in Grizzly release and there were patches regarding multipath added even 
after the Grizzly release.  EMC VNX5300 should work with iSCSI multipath with 
Grizzly and beyond.

Thanks,
Xing



-----Original Message-----
From: Takashi Natsume [mailto:natsume.taka...@lab.ntt.co.jp] 
Sent: Monday, November 25, 2013 6:07 AM
To: yang, xing; openstack@lists.openstack.org
Subject: RE: [Openstack] multipath - EMC vs NetApp

Hello Xing and all,

We tried to set up iSCSI multipath with EMC VNX5300.
However, we had some problems with setting the iSCSI multipath with EMC VNX5300.
So, we analyzed the logs and source codes, and found out that nova-compute 
(cinder-volume also same) is using a single iSCSI target(IQN) for login to 
multiple (different) portal IP addresses.
VNX5300 has multiple iSCSI ports with different iSCSI target (IQN)s.
(Normally it should use a different iSCSI target(IQN) for each IP address.)

So, we realized that, iSCSI multipath cannot be configured with VNX5300.
But we would like to use iSCSI multipath with EMC VNX5300.

Regards,
Takashi Natsume
NTT Software Innovation Center
Tel: +81-422-59-4399
E-mail: natsume.taka...@lab.ntt.co.jp

From: yang, xing [mailto:xing.y...@emc.com]
Sent: Friday, November 22, 2013 7:25 AM
To: Carlos Alvarez; openstack@lists.openstack.org
Subject: Re: [Openstack] multipath - EMC vs NetApp

Hi Carlos,

We are working on this issue and will keep you informed.

Thanks,
Xing


From: Carlos Alvarez [mailto:cbalva...@gmail.com]
Sent: Monday, November 18, 2013 1:19 PM
To: openstack@lists.openstack.org
Subject: [Openstack] multipath - EMC vs NetApp

Hi All.

I recently added a EMC V-Max storage system, and realized the multipath is not 
working. The device is called /dev/mapper/XXXX but when I see the multipath -ll 
output, I see just one path. It is working fine with a NetApp 3250. 

Looking into differences, I see the output of the iscsiadm discovery
differs:

Netapp output:
root@grizzly-dev04:~# iscsiadm -m discovery -t sendtargets -p 10.33.5.10
10.33.5.10:3260,1030
iqn.1992-08.com.netapp:sn.0e3c22d9f2ea11e2a2f2123478563412:vs.10
10.33.5.11:3260,1031
iqn.1992-08.com.netapp:sn.0e3c22d9f2ea11e2a2f2123478563412:vs.10

Emc output:
root@grizzly-dev04:~# iscsiadm -m discovery -t sendtargets -p 10.33.5.25
10.33.5.25:3260,1 iqn.1992-04.com.emc:50000973f00bcd44


Looking into the code, the former is clearly what the connect_volume method is 
expecting: a single ip which returns both path. I reported it to EMC and the 
answer is that it works with netapp because the 3250 has a feature EMC lacks 
(called multipath groups). 

Is anybody using multipath with a V-Max?. It should work or EMC is not 
supported?

Thanks!
Carlos




_______________________________________________
Mailing list: http://lists.openstack.org/cgi-bin/mailman/listinfo/openstack
Post to     : openstack@lists.openstack.org
Unsubscribe : http://lists.openstack.org/cgi-bin/mailman/listinfo/openstack

Reply via email to