On 2015-07-21 22:45, Michael Still wrote: > We therefore propose the following: > > - all operators when they hit Liberty will need to add a new > connection string to their nova.conf which configures this new mysql > database, there will be a release note to remind you to do this. > - we will add a flag which indicates if a db_sync should imply a sync > of the cells database as well. The default for this flag will be true. > > This means that you can still do these syncs separately if you want, > but we're not forcing you to remember to do it if you just want it to > always happen at the same time. > > Does this sound acceptable? Or are we over thinking this? We'd > appreciate your thoughts.
as an op I would like to know if nova can work with the db at different shema level nova api = N nova db = N nova cell db = M nova compute = M & N I have no problem doing the db updates in certain order (example: nova db before nova cell db) but I want to be able to keep running if the second db upgrade fails and I need more time to fix it. a grenade job in the gate testing that would be great -- 1AE0 322E B8F7 4717 BDEA BF1D 44BB 1BA7 9F6C 6333 keybase: http://keybase.io/gfa _______________________________________________ OpenStack-operators mailing list OpenStack-operators@lists.openstack.org http://lists.openstack.org/cgi-bin/mailman/listinfo/openstack-operators