Hi,

I took a look at the Dell PowerEdge R370xd Rack Server web page, 
http://www.dell.com/en-us/work/shop/povw/poweredge-r730xd.  It states that 
Microsoft Windows Server 2008 R2 (W2K8 R2) is supported.

From what you described, it sounds like the issue is that W2K8 R2 does not have 
the device drivers needed for the RAID controller.  I found a Dell OS Driver 
Pack for W2K8 R2 web page, 
http://www.dell.com/support/home/us/en/19/drivers/driversdetails?driverId=MRW6J&fileId=1943535120&osCode=W12R2&productCode=poweredge-r730xd&languageCode=en&categoryId=DD.
  Please note that it states that it does not support W2K8 R2 Service Pack 1 
(SP1).  A driver pack download is available there.  The installation 
instructions on that page are a bit involved; you may have to copy the file to 
a USB driver, plug the USB into the server, boot into the Lifecycle Controller, 
etc., etc.

In the end, while Dell supports that operating system on that server, it does 
not look like ironic will unless you can make a QCOW2 image that has the 
necessary device drivers in it.  I am not sure how exactly to do that.  It 
might be easier to just go with Microsoft Windows Server 2016, which probably 
has the necessary drivers, since there is no OS driver pack for that operating 
system on the Dell support site.

Kind regards,
Rick

From: 王俊 [mailto:wang...@yovole.com]
Sent: Thursday, August 24, 2017 10:36 PM
To: Pioso, Richard <richard_pi...@dell.com>
Subject: 答复: [ironic-drac-driver]does drac-driver only support 11th or 12th 
generation of Dell PowerEdge servers?

Hi Richard:
         Does R730xd support windows2008r2 sp1?I deploy the user image 
success,but it can’t be step in windows system,then I try to install window2008 
with local image(xxx.iso). I can not continue because of it can’t find no-raid 
disk or virtual disk which made by raid configure.
        Can you give me some suggestion?

发件人: richard.pi...@dell.com<mailto:richard.pi...@dell.com> 
[mailto:richard.pi...@dell.com]
发送时间: 2017年8月22日 23:28
收件人: 王俊 <wang...@yovole.com<mailto:wang...@yovole.com>>
主题: RE: [ironic-drac-driver]does drac-driver only support 11th or 12th 
generation of Dell PowerEdge servers?

Thank you for contacting me.  No bother at all.

I have never seen that error.  It does not appear to be specific to the iDRAC 
driver.

I recommend using IRC for help with this one.

Kind regards,
Rick

From: 王俊 [mailto:wang...@yovole.com]
Sent: Tuesday, August 22, 2017 2:23 AM
To: Pioso, Richard <richard_pi...@dell.com<mailto:richard_pi...@dell.com>>
Subject: 答复: [ironic-drac-driver]does drac-driver only support 11th or 12th 
generation of Dell PowerEdge servers?

Sorry  to bother you, I have a problem with install user image, the deploy log 
said like this:

Aug 22 07:40:42 ubuntu ironic-python-agent[1896]: Command: iscsistart -f
Aug 22 07:40:42 ubuntu ironic-python-agent[1896]: Exit code: 21
Aug 22 07:40:42 ubuntu ironic-python-agent[1896]: Stdout: u'Could not get list 
of targets from firmware.\n'
Aug 22 07:40:42 ubuntu ironic-python-agent[1896]: Stderr: u'' _check_for_iscsi 
/usr/share/ironic-python-agent/venv/local/lib/python2.7/site-packages/ironic_python_agent/hardware.py:91

And this:

Aug 22 07:41:27 ubuntu ureadahead[330]: 
ureadahead:/etc/sysctl.d/10-ipv6-privacy.conf: Error retrieving chunk extents: 
Operation not supported
Aug 22 07:41:27 ubuntu ureadahead[330]: 
ureadahead:/etc/sysctl.d/10-kernel-hardening.conf: Error retrieving chunk 
extents: Operation not supported
Aug 22 07:41:27 ubuntu ureadahead[330]: 
ureadahead:/etc/sysctl.d/10-link-restrictions.conf: Error retrieving chunk 
extents: Operation not supported
Aug 22 07:41:27 ubuntu ureadahead[330]: 
ureadahead:/etc/sysctl.d/10-magic-sysrq.conf: Error retrieving chunk extents: 
Operation not supported
Aug 22 07:41:27 ubuntu ureadahead[330]: 
ureadahead:/etc/sysctl.d/10-network-security.conf: Error retrieving chunk 
extents: Operation not supported

Do you ever seen it before?

发件人: richard.pi...@dell.com<mailto:richard.pi...@dell.com> 
[mailto:richard.pi...@dell.com]
发送时间: 2017年8月18日 6:05
收件人: 王俊 <wang...@yovole.com<mailto:wang...@yovole.com>>
主题: RE: [ironic-drac-driver]does drac-driver only support 11th or 12th 
generation of Dell PowerEdge servers?

Congratulations!  I am glad to hear that you have gotten by that issue.

Happy to help.

Regards,
Rick

From: 王俊 [mailto:wang...@yovole.com]
Sent: Wednesday, August 16, 2017 11:18 PM
To: Pioso, Richard <richard_pi...@dell.com<mailto:richard_pi...@dell.com>>
Subject: 答复: [ironic-drac-driver]does drac-driver only support 11th or 12th 
generation of Dell PowerEdge servers?

I know what’s the problem.I saw the log in deploy image system whitch create by 
IPA, url_api is wrong.
Thanks a lot

发件人: 王俊
发送时间: 2017年8月17日 9:07
收件人: 'richard.pi...@dell.com' 
<richard.pi...@dell.com<mailto:richard.pi...@dell.com>>
主题: 答复: [ironic-drac-driver]does drac-driver only support 11th or 12th 
generation of Dell PowerEdge servers?

I was in #openstack-ironic all day,but nobody can answer my question about 
drac-driver.maybe I should read the code to know how  process run. 
Ironic-conductor.log haven’t any error info about process timeout.
发件人: richard.pi...@dell.com<mailto:richard.pi...@dell.com> 
[mailto:richard.pi...@dell.com]
发送时间: 2017年8月16日 20:16
收件人: 王俊 <wang...@yovole.com<mailto:wang...@yovole.com>>
主题: RE: [ironic-drac-driver]does drac-driver only support 11th or 12th 
generation of Dell PowerEdge servers?

Hi,

Yes, the ironic iDRAC drivers support Dell 13G servers, including the PowerEdge 
730xd.

Regarding the current issue, please take a look at the Ironic Conductor log to 
gain some insight into what caused node cleaning to fail.  It is located in 
/var/log/ironic.

I would like to recommend an excellent ironic support resource to you,  
Internet Relay Chat (IRC).  Please see 
https://wiki.openstack.org/wiki/Ironic#IRC for more details.  The ironic 
community is extraordinarily welcoming and helpful.

Thank you, and regards,
Rick

From: 王俊 [mailto:wang...@yovole.com]
Sent: Wednesday, August 16, 2017 4:08 AM
To: Pioso, Richard <richard_pi...@dell.com<mailto:richard_pi...@dell.com>>
Subject: 答复: [ironic-drac-driver]does drac-driver only support 11th or 12th 
generation of Dell PowerEdge servers?

I am testing on PowerEdge R730xd, 13th generation server. Drac-driver support 
it?
发件人: 王俊
发送时间: 2017年8月16日 15:42
收件人: richard.pi...@dell.com<mailto:richard.pi...@dell.com>
主题: [ironic-drac-driver]does drac-driver only support 11th or 12th generation 
of Dell PowerEdge servers?

Hi
I have already fix the network,but it still have some problem. When I make the 
node status to provide, I can see the deploy image boot in the node,and the 
deploy system seems OK in the DELL server node.But it’s motionless.After for a 
long time, the deploy system shutdown and ironic show me the node clean failed. 
The reason is time out. I don’t know why

tks

发件人: 王俊
发送时间: 2017年8月15日 19:56
收件人: richard.pi...@dell.com<mailto:richard.pi...@dell.com>
主题: RE: [ironic-drac-driver]does drac-driver only support 11th or 12th 
generation of Dell PowerEdge servers?

I configure NIC port , I can ping into the Ip which configured by DHCP .but I 
can't ping into the gateway .may be I should fix this first

来自 魅蓝 Note5



-------- 原始邮件 --------
发件人:richard.pi...@dell.com<mailto:richard.pi...@dell.com>
时间:周二 8月15日 19:26
收件人:王俊 <wang...@yovole.com<mailto:wang...@yovole.com>>
主题:RE: [ironic-drac-driver]does drac-driver only support 11th or 12th 
generation of Dell PowerEdge servers?
Hi,

It sounds like the server is not attempting to PXE boot.  The iDRAC web 
client’s console feature can be used to determine that.  Has a network 
interface card (NIC) port been configured to PXE boot?

Thank you, and regards,
Rick

From: 王俊 [mailto:wang...@yovole.com]
Sent: Tuesday, August 15, 2017 5:25 AM
To: Pioso, Richard <richard_pi...@dell.com<mailto:richard_pi...@dell.com>>
Subject: 答复: [ironic-drac-driver]does drac-driver only support 11th or 12th 
generation of Dell PowerEdge servers?

After I deleted all virtual disks, the virtual control show me “No boot device 
available”

发件人: 王俊
发送时间: 2017年8月15日 16:54
收件人: 'richard.pi...@dell.com' 
<richard.pi...@dell.com<mailto:richard.pi...@dell.com>>
主题: 答复: [ironic-drac-driver]does drac-driver only support 11th or 12th 
generation of Dell PowerEdge servers?

Hi:
Do you have any documents about drac driver configuration? When I use CLI to 
make My environment in provide,the server setp in a system which I install use 
local image.for a long time, the node provision_state is clean failed. The 
maintenance_reason is “Timeout reached while cleaning the node. Please check if 
the ramdisk     responsible for the cleaning is running on the node. Failed on 
step {}.”
I don’t know how to fix it

Regards

发件人: richard.pi...@dell.com<mailto:richard.pi...@dell.com> 
[mailto:richard.pi...@dell.com]
发送时间: 2017年8月15日 12:19
收件人: 王俊 <wang...@yovole.com<mailto:wang...@yovole.com>>
抄送: openstack-dev@lists.openstack.org<mailto:openstack-dev@lists.openstack.org>
主题: RE: [ironic-drac-driver]does drac-driver only support 11th or 12th 
generation of Dell PowerEdge servers?

Hi,

Thank you for your e-mail.  I would be glad to assist you with the issues that 
you have found in the ironic drivers for the Dell EMC integrated Dell Remote 
Access Controller (iDRAC).  The same applies to any questions you may have 
about them.

I look forward to working with you.

Kind regards,
Rick


Richard G. Pioso
Software Senior Principal Engineer
Ready Solutions & Alliances
Dell EMC | Converged Platforms Solutions Division
richard.pi...@dell.com<mailto:richard.pi...@dell.com>

From: 王俊 [mailto:wang...@yovole.com]
Sent: Sunday, August 13, 2017 11:20 PM
To: openstack-dev@lists.openstack.org<mailto:openstack-dev@lists.openstack.org>
Subject: [openstack-dev] [ironic-drac-driver]does drac-driver only support 11th 
or 12th generation of Dell PowerEdge servers?

Hi,
         Who know about drac-driver?I find some mistakes in 13th generation of 
Dell PowerEdge server.such as PowerEdge R730xd

保密:本函仅供收件人使用,如阁下并非抬头标明的收件人,请您即刻删除本函,勿以任何方式使用及传播,并请您能将此误发情形通知发件人,谢谢!

保密:本函仅供收件人使用,如阁下并非抬头标明的收件人,请您即刻删除本函,勿以任何方式使用及传播,并请您能将此误发情形通知发件人,谢谢!

保密:本函仅供收件人使用,如阁下并非抬头标明的收件人,请您即刻删除本函,勿以任何方式使用及传播,并请您能将此误发情形通知发件人,谢谢!

保密:本函仅供收件人使用,如阁下并非抬头标明的收件人,请您即刻删除本函,勿以任何方式使用及传播,并请您能将此误发情形通知发件人,谢谢!

保密:本函仅供收件人使用,如阁下并非抬头标明的收件人,请您即刻删除本函,勿以任何方式使用及传播,并请您能将此误发情形通知发件人,谢谢!

保密:本函仅供收件人使用,如阁下并非抬头标明的收件人,请您即刻删除本函,勿以任何方式使用及传播,并请您能将此误发情形通知发件人,谢谢!
__________________________________________________________________________
OpenStack Development Mailing List (not for usage questions)
Unsubscribe: openstack-dev-requ...@lists.openstack.org?subject:unsubscribe
http://lists.openstack.org/cgi-bin/mailman/listinfo/openstack-dev

Reply via email to