Hi Folks, I have a change submitted which adds the same clean shutdown logic to stop and delete that exists for soft reboot - the rational being that its always better to give a VM a chance to shutdown cleanly if possible even if you're about to delete it as sometimes other parts of the application expect this, and if its booted from a volume you want to leave the guest file system in a tidy state.
https://review.openstack.org/#/c/35303/ However setting the default value to 120 seconds (as per soft reboot) causes the Jenkins gate jobs to blow the 3 hour limit. This seems to be just a gradual accumulation of extra time rather than any one test running much longer. So options would seem to be: i) Make the default wait time much shorter so that Jenkins runs OK (tries this with 10 seconds and it works fine), and assume that users will configure it to a more realistic value. ii) Keep the default at 120 seconds, but make the Jenkins jobs use a specific configuration setting (is this possible, and iof so can someone point me at where to make the change) ? iii) Increase the time allowed for Jenkins iv) The ever popular something else ... Thought please. Cheers, Phil
_______________________________________________ OpenStack-dev mailing list OpenStack-dev@lists.openstack.org http://lists.openstack.org/cgi-bin/mailman/listinfo/openstack-dev